3.6.6 Remote Inhibit

– J22-36 / J22-27

The Remote Inhibit input J22 pin 36 can be used to open and close the output relay of the AC
power source. This input overrides the state of the output relay programmed from the front panel
or the bus. It may be used for safety interlock purposes.

A logic low on this pin will cause the output voltages to be programmed to 0.0 volts and the output
relays to open. A logic high will cause the programmed output voltage to be restored at the output
terminals. A contact closure between pin J22-36 and pin J22-27 (D COM) will simulate a logic low
state.