This section of the manual covers operation of the

–160 option using the CIGui32 program.

Version 1.26 or higher of the CIGui32 program is required. The CIGui32 program is supplied with
all iX systems free of charge on CD ROM CIC496. It can also be downloaded from the California
Instruments web site (

www.calinst.com

).

The information provided in this user manual is aimed at guiding the operator in the use of the
160 option through the use of the CIGui32 program. Much of the same information can be found
in the on-line help system of the CIGUI32.

This manual is not intended to elaborate on the intent or purpose of the immunity tests and the
expected behavior of the EUT as described in the RTCA/DO-160 documents. It is assumed that
the end-user is familiar with the content of the RTCA/DO-160 test standard.

9.1.2.2 Test Coverage

The comprehensiveness of the tests that can be performed with the

–160 option is determined

primarily by the capabilities of the power source used. Tests that are outside the hardware
capabilities of the power source used will not be enabled and cannot be selected. For these
tests, additional equipment may be required as indicated. The extent of coverage of the

–160

option as implemented on the iX Series platform is shown in the table below. Tests marked with
an „x‟ generally require additional hardware to be used. Tests marked „N/A‟ are not applicable to
the corresponding table. Tests marked with a „ ‟ are covered by the –160 option. Tests marked
with a „P‟ are limited in scope and may require additional equipment to perform completely.

No.

115V Tests
Description

Table
A(CF)

Table
A(NF)

Table

A(WF)

No.

28 VDC Tests
Description

Table

ADC

Table

BDC

Table

ZDC

16.5.1.1

Voltage and
Frequency

16.6.1.1

Voltage

16.5.1.2

Voltage Modulation

16.6.1.2

Ripple Voltage

P

P

P

16.5.1.3

Frequency
Modulation

16.6.1.3

Momentary Power
Interruptions

16.5.1.4

Momentary Power
Interruptions

16.6.1.4

Normal Surge
Voltage

16.5.1.5.1

Normal Surge
Voltage

16.6.1.5

Engine Starting
Under Voltage

N/A

16.5.1.5.2

Normal Frequency
Transients

N/A

N/A

16.6.2.1

Abnormal Voltage

16.5.1.6

Normal Frequency
Variations

N/A

16.6.2.2

Low Voltage
Conditions

N/A

N/A

16.5.1.7

Voltage DC
Content

16.6.2.3

Momentary Under
Voltage Operation

16.5.1.8

Voltage Distortion

P

P

P

16.6.2.4

Abnormal Voltage
Surge

16.5.2.1

Abnormal Voltage
and Frequency

16.5.2.2

Momentary Under
Voltage Operation

16.5.2.3.1

Abnormal Surge
Voltage

16.5.2.3.2

Abnormal
Frequency
Transient

N/A

N/A

Table 9-17: -160 Option Test Coverage, 115VAC and 28VDC