2.1.3 Measurements (i series)

Parameter

Range

Accuracy ( )

Resolution

Frequency

16.00 - 99.99 Hz
100.0 - 500.0 Hz

0.02 Hz
0.2 Hz

0.01 Hz
0.1 Hz

Rms Voltage

0 - 300 Volts

0.5V

0.01 Volt

Rms Current

0 - 40 Amps

0.5A

0.001 Amp

Peak Current

0 - 119 Amps

0.5A

0.001 Amp

VA Power

0 - 6.000 kVA

0.2 kVA

0.001 kVA

Real Power

0 - 6.000 kW

0.05 kW

0.001 kW

Power Factor
(>0.2kVA)

0 - 1.00

0.02

0.01

Current and Power Accuracy specifications are times ten for 10001i and 15001i. For 10001i and 15001i, resolution
decreases by factor of 10, ranges for current and power increases by factor of ten.

2.1.4 AC Measurements (iX series)

Parameter

Range

Accuracy ( )

Resolution

Frequency

16.00 - 500.0 Hz

0.01% + 0.01 Hz

0.01 to 81.91 Hz
0.1 to 500 Hz

RMS Voltage

0 - 300 Volts

0.05V + 0.02%, <100 Hz

0. 1V + 0.02%, 100-500 Hz

0.01 Volt

RMS Current

0 - 40 Amps

0.05A + 0.02%, <100 Hz

0. 1A + 0.02%, 100-500 Hz

0.001 Amp

Peak Current

0 - 119 Amps

0.05A + 0.02%, <100 Hz

0. 1A + 0.02%, 100-500 Hz

0.001 Amp

VA Power

0 - 6.000 kVA

0.01kVA + 0.02%, <100 Hz

0. 02kVa + 0.02%, 100-500 Hz

0.001 kVA

Real Power

0 - 6.000 kW

0.005kW + 0.02%, <100 Hz

0.01kW + 0.02%, 100-500 Hz

0.001 kW

Power Factor
(>0.2kVA)

0 - 1.00

0.01