AMETEK i Series User Manual
Page 215

User Manual
i Series / iX Series
201
(limited by 5001iX / 15003iX)
at 0% U
NOM
N/A
N/A
Bypass Mode Engaged:
Maximum Current
37 A
RMS
37 A
RMS
/phase
9.4.4.3 Controls/Indicators
Control / Indicator
Comments
ON/OFF toggle switch
70 / 80 Tap Select toggle switch
(EOS1, second generation only).
Power On lamp
Active lamp
Fault lamp
9.4.4.4 Mechanical
Dimensions
7"H x 19"W x 24"D
178 mm H x 483 mm W x 610 mm D
Weight
EOS-1
70 lbs, 32 kg
EOS-3
160 lbs, 73 kg
Connectors:
Input mains
IEC 320
Source
Compression
Load
Compression
Option In/Out
9 pin D-subminiature
Chassis Slide
General Devices C300S-120-B308
9.4.4.5 Environmental
Temperature
0 to 40 °C
Relative Humidity
80% max. to 31 °C
derate linearly to 50% max. at 40°C
Altitude
2000 m max.
Installation Over voltage Category
II
Pollution Degree
2
Equipment Class
I
Usage
Indoors