7.4 Advanced Troubleshooting.

WARNING:

Do not connect 400-480V into the 208-240V unit, the result could be

a severely damaged unit.

CAUTION:

VOLTAGES UP TO 480 VAC AND 700 VDC ARE PRESENT IN

CERTAIN SECTIONS OF THIS POWER SOURCE.

WARNING:

THIS EQUIPMENT GENERATES POTENTIALLY LETHAL

VOLTAGES. DEATH ON CONTACT MAY RESULT IF PERSONNEL FAIL TO
OBSERVE SAFETY PRECAUTIONS. DO NOT TOUCH ELECTRONIC CIRCUITS
WHEN POWER IS APPLIED

7.4.1 Switch Off Unit

Switch of the unit at the circuit breaker on the front panel as well as removing the input power
from the unit.

WARNING:

Wait 10 minutes for all internal capacitors to discharge.

7.4.2 Removing Top Cover

Remove the screws securing the top cover and remove the top cover.

7.4.3 Initial Inspection

Make a visual inspection of the unit and ensure all the connectors are properly mated and there
are no loose or broken wires.