User Manual

i Series / iX Series

149

VOLT SURGE

This test will produce voltage surge defined by Table 9-16. This test will be repeated three times
with ten seconds intervals. The voltage values are halved for 14.0V category B equipment.

Category

Surge 1

Surge 2

Volt

Dwell(msec)

Volt

Dwell(msec)

A

46.3

100

37.8

1000

B

60

100

40

1000

Z

80

100

48

1000

Table 9-16: Abnormal Voltage Surge

9.1.1.6.3 Emergency Test

The Emergency test is selected from the DO-160 DC Main Menu. This test will set the output
voltage to 18V for 28V equipment and to 9V for 14V equipment. The test will last for 30 minutes.
The

key (backspace) will terminate the test at any time.