OMNI Type

1-18i, 3-18i, 1-37i, 3-37i

1-37iJ

Impedance ± 5%

(in combination with power source output impedance)

Phase

0.24 ohms + j 0.15 ohms at 50 Hz

0.24 ohms + j 0.062 ohms at 50 Hz

Neutral

0.16 ohms + j 0.10 ohms at 50 Hz

0.16 ohms + j 0.054 ohms at 50 Hz

9.6.3.3 Controls/Indicators

ON/OFF toggle switch
Flicker On/Off push button switch
Power Lamp
Bypass Lamp
Flicker Lamp

9.6.3.4 Mechanical

Dimensions

Omni 1-18i and 3-18i: Omni 1-37i, 1-37iJ and 3-37i:

3.5"H x 19"W x 22"D 5.25”H x 19”W x 22”D

89mmH x 480mmW x 560mmD 133mmH x 480mmW x
560mmD

Weight

OMNI-1-18i

OMNI-3-18i

OMNI-1-37iJ

OMNI-3-37i


31 lb. (14 kg)

37 lb. (17 kg)

55 lb. (25 kg)

55 lb. (25 kg)

Connectors

Input AC

Impedance Network

Input and Output

System Interface

IEC 320

Kulka 9-85 series

3M 3367-1000 (mates with 3M 3366-1001)

Chassis Slide

General Devices C300S-118-U/B308 BK

9.6.4 Installation and Acceptance

9.6.4.1 Unpacking

Inspect the unit for any possible shipping damage immediately upon receipt. If damage is
evident, notify the carrier. Do not return an instrument to the factory without prior approval. Do
not destroy the packing container until the unit has been inspected for damage in shipment.

9.6.4.2 Power Requirements

The OMNI 1-18i and 3-18i use either 115 or 230 VAC to power the control circuits. The user
may select the desired input voltage using the small range selector card within the IEC input