beautypg.com

AMETEK i Series User Manual

Page 290

background image

User Manual

276

i Series / iX Series

Test No. Section

Subject

Test Limits

Comment

File Ref.

LDC105

Normal Voltage Transients

18V to 50V DC

1

Overvoltage Transients

Peak Voltage 50V DC

Table LDC105-3 AA-JJ

FLDC105-1

2

Undervoltage Transients

Low Voltage 18V DC

Table LDC105-3 KK-PP

FLDC105-2

3

Combined Transients

18V to 50V DC

Table LDC105-3 QQ-RR

FLDC105-3

4

Repetitive Normal Voltage Transient Test

18V to 45V DC

Repeat transient for 30 mins

FLDC105-4

LDC201

Power Interrupt

0V for 50 msec

Table LDC201-2 A-L

FLDC201

LDC301

Abnormal Steady State Limits for Voltage

20V to 31.5V DC

Apply each test for 30 mins

FLDC301

LDC302

Abnormal Voltage Transients

7V to 50V DC

1

Overvoltage Transients

Peak Voltage 50V DC

Table LDC302-4 AAA-FFF

FLDC302-1

2

Undervoltage Transients

Low Voltage 7V DC

Table LDC302-4 GGG-LLL

FLDC302-2

3

Combined Transients

7V to 50V DC

Table LDC302-4 MMM-NNN

FLDC302-3

LDC401

Emergency Limits for Voltage

18V to 29V DC

Apply each test for 30 mins

FLDC401

LDC501

Starting Voltage Transients

12V to 29V DC

Table LDC501-3 AA

FLDC501

LDC601

Power Failure

0V for 7 seconds

Table LDC601-2 A-D

FLDC601

LDC602

Polarity Reversal

Polarity reversal done physically FLDC602

Table HDC:

Test No. Section

Subject

Test Limits

Comment

File Ref.

HDC101

Load Measurements

270V DC

FHDC101

HDC102

Steady State Limits for Voltage

250V to 280V DC

Apply for 30 mins

FHDC102

HDC103

Voltage Distortion Spectrum

Requires Additional Equipment

HDC104

Total Ripple

Requires Additional Equipment

HDC105

Normal Voltage Transients

200V to 330V DC

1

Overvoltage Transients

Peak Voltage 330V DC

Table HDC105-2 AA-JJ

FHDC105-1

2

Undervoltage Transients

Low Voltage 200V DC

Table HDC105-2 KK-PP

FHDC105-2

3

Combined Transients

200V to 330V DC

Table HDC105-2 QQ-RR

FHDC105-3

4

Repetitive Normal Voltage Transient Test

215V to 315V DC

Repeat transient for 30 mins

FHDC105-4

HDC201

Power Interrupt

0V for 50 msec

Table HDC201-2 A-L

FHDC201

HDC301

Abnormal Steady State Limits for Voltage

240V to 290V DC

Apply each test for 30 mins

FHDC301

HDC302

Abnormal Voltage Transients

180V to 350V DC

1

Overvoltage Transients

Peak Voltage 350V DC

Table HDC302-4 AAA-FFF

FHDC302-1

2

Undervoltage Transients

Low Voltage 180V DC

Table HDC302-4 GGG-LLL

FHDC302-2

3

Combined Transients

180V to 350V DC

Table HDC302-4 MMM-NNN

FHDC302-3

HDC401

Emergency Limits for Voltage

250V to 280V DC

Apply each test for 30 mins

FHDC401

HDC501

Starting Voltage Transients

115V to 280V DC

Table HDC501-3 AA

FHDC501

HDC601

Power Failure

0V for 7 seconds

Table HDC601-2 A-D

FHDC601

HDC602

Polarity Reversal

Polarity reversal done physically

FHDC602

Rev E:

This test should be performed using the firmware version of the

–704 option.

Rev D:

This test should be performed using the firmware version of the

–704 option.