J22

Description

sync input. It connects to the cathode of an LED at the input of an optocoupler. Refer to
J22-32.

16

AMP SHARE B

17

PARALLEL

18

CL ENA

19

MR C: Phase C master signal

20

MR A: Phase A master signal

21

CS C: Phase C current sum

22

CS A: Phase A current sum

23

OSC C: Phase C oscillator output

24

OSC A: Phase A oscillator output

25

CL C: Phase C current limit reference

26

CL A: Phase A current limit reference

27

D COM: Digital Common

28

RNG HI: Voltage range state: Logic HI = high range, LOW = low range

29

: Overload

30

FLT B: Phase B current limit fault control

31

F STB HI: Function Strobe / Trigger output HI. A low-going pulse, >400 s, that indicates
voltage or frequency change. Isolated output that requires a pull-up resistor, 22K , to +5
VDC. Use J22 pin 14 (F STB LO) for common. See section 3.6.5 for details.

32

EX SYNC HI, External Sync input HI. This is an input that can be used to synchronize the
outputs of the AC Power System. This input requires a logic high level of at least +4.5
VDC at 5 mA. The input should have a duty cycle 50 30%. J22-15 is the common input.
The External Sync input is optically isolated. It must be enabled from the SNC screen.

33

AMP SHARE C

34

AMP SHARE A

35

FLICKER /

36

REMOTE ON: This is a logic input that can be used to remove the programmed output
voltage. A logic low on this pin will cause the output voltages to be programmed to 0.0
volts and the output relays to open. A logic high will cause the programmed output
voltage to be restored at the output terminals. A contact closure between this pin and
J22-27 (D COM) will simulate a logic low state.