272
i Series / iX Series
Test No. Section
Subject
Test Limits
Comment
File Ref.
1
Overfrequency Transients
High Frequency 800 Hz
Table SVF303-2 A-D
FSVF303-1
2
Underfrequency Transients
Low Frequency 360 Hz
Table SVF303-2 E-H
FSVF303-2
3
Combined Transient
360 Hz to 800 Hz
Table SVF303-2 I
FSVF303-3
SVF401
Emergency Limits for Voltage and Frequency
Perform Test SVF102
SVF501
No Tests
N/A to AC Utilization Equipment
SVF601
Power Failure (Single Phase)
400-1 115V RMS, 400 Hz nominal settings
0V for 7 seconds
Table SVF601-2
FSVF601-400-1
360-1 115V RMS, 360 Hz nominal settings
0V for 7 seconds
Table SVF601-2
FSVF601-360-1
600-1 115V RMS, 600 Hz nominal settings
0V for 7 seconds
Table SVF601-2
FSVF601-600-1
800-1 115V RMS, 800 Hz nominal settings
0V for 7 seconds
Table SVF601-2
FSVF601-800-1
SVF602
No Test, Done so numbers coincide
SVF603
Phase Reversal
Phase reversal done physically
FSVF603
Table TVF:
Test No. Section
Subject
Test Limits
Comment
File Ref.
TVF101
Load and Current Harmonic Measurements
115V RMS, 360-800 Hz
FTVF101
TVF102
Steady State Limits for Voltage (Including Unbalance) and Frequency
1
Balanced Phases
108V to 118V RMS, 360 to 800 Hz Apply for 30 mins each test
FTVF102-1
2
Unbalanced Phases
108V to 118V RMS, +/- 3V
Unbalance
Apply for 30 mins each test
FTVF102-2
TVF103
Voltage Phase Difference
400-1 115V RMS, 400 Hz nominal settings
Phase B 116 to 124 degrees
Apply for 30 mins each test
FTVF103-400-1
360-1 115V RMS, 360 Hz nominal settings
Phase B 116 to 124 degrees
Apply for 30 mins each test
FTVF103-360-1
600-1 115V RMS, 600 Hz nominal settings
Phase B 116 to 124 degrees
Apply for 30 mins each test
FTVF103-600-1
800-1 115V RMS, 800 Hz nominal settings
Phase B 116 to 124 degrees
Apply for 30 mins each test
FTVF103-800-1
TVF104
Voltage Modulation
400-1 115V RMS, 400 Hz nominal settings
115V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-400-1
400-2 109V RMS, 400 Hz nominal settings
109V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-400-2
400-3 117V RMS, 400 Hz nominal settings
117V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-400-3
360-1 115V RMS, 360 Hz nominal settings
115V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-360-1
360-2 109V RMS, 360 Hz nominal settings
109V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-360-2
360-3 117V RMS, 360 Hz nominal settings
117V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-360-3
600-1 115V RMS, 600 Hz nominal settings
115V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-600-1
600-2 109V RMS, 600 Hz nominal settings
109V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-600-2
600-3 117V RMS, 600 Hz nominal settings
117V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-600-3
800-1 115V RMS, 800 Hz nominal settings
115V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-800-1
800-2 109V RMS, 800 Hz nominal settings
109V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-800-2
800-3 117V RMS, 800 Hz nominal settings
117V RMS, 2.5V RMS mod
Apply for 10+ mins
FTVF104-800-3
TVF105
Frequency Modulation
400-1 115V RMS, 400 Hz nominal settings
400 Hz, 4 Hz mod
Apply for 30+ mins
FTVF105-400-1
360-1 115V RMS, 360 Hz nominal settings
360 Hz, 4 Hz mod
Apply for 30+ mins
FTVF105-360-1
600-1 115V RMS, 600 Hz nominal settings
600 Hz, 4 Hz mod
Apply for 30+ mins
FTVF105-600-1