Test No. Section

Subject

Test Limits

Comment

File Ref.

1

Overfrequency Transients

High Frequency 800 Hz

Table SVF303-2 A-D

FSVF303-1

2

Underfrequency Transients

Low Frequency 360 Hz

Table SVF303-2 E-H

FSVF303-2

3

Combined Transient

360 Hz to 800 Hz

Table SVF303-2 I

FSVF303-3

SVF401

Emergency Limits for Voltage and Frequency

Perform Test SVF102

SVF501

No Tests

N/A to AC Utilization Equipment

SVF601

Power Failure (Single Phase)

400-1 115V RMS, 400 Hz nominal settings

0V for 7 seconds

Table SVF601-2

FSVF601-400-1

360-1 115V RMS, 360 Hz nominal settings

0V for 7 seconds

Table SVF601-2

FSVF601-360-1

600-1 115V RMS, 600 Hz nominal settings

0V for 7 seconds

Table SVF601-2

FSVF601-600-1

800-1 115V RMS, 800 Hz nominal settings

0V for 7 seconds

Table SVF601-2

FSVF601-800-1

SVF602

No Test, Done so numbers coincide

SVF603

Phase Reversal

Phase reversal done physically

FSVF603

Table TVF:

Test No. Section

Subject

Test Limits

Comment

File Ref.

TVF101

Load and Current Harmonic Measurements

115V RMS, 360-800 Hz

FTVF101

TVF102

Steady State Limits for Voltage (Including Unbalance) and Frequency

1

Balanced Phases

108V to 118V RMS, 360 to 800 Hz Apply for 30 mins each test

FTVF102-1

2

Unbalanced Phases

108V to 118V RMS, +/- 3V
Unbalance

Apply for 30 mins each test

FTVF102-2

TVF103

Voltage Phase Difference

400-1 115V RMS, 400 Hz nominal settings

Phase B 116 to 124 degrees

Apply for 30 mins each test

FTVF103-400-1

360-1 115V RMS, 360 Hz nominal settings

Phase B 116 to 124 degrees

Apply for 30 mins each test

FTVF103-360-1

600-1 115V RMS, 600 Hz nominal settings

Phase B 116 to 124 degrees

Apply for 30 mins each test

FTVF103-600-1

800-1 115V RMS, 800 Hz nominal settings

Phase B 116 to 124 degrees

Apply for 30 mins each test

FTVF103-800-1

TVF104

Voltage Modulation

400-1 115V RMS, 400 Hz nominal settings

115V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-400-1

400-2 109V RMS, 400 Hz nominal settings

109V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-400-2

400-3 117V RMS, 400 Hz nominal settings

117V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-400-3

360-1 115V RMS, 360 Hz nominal settings

115V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-360-1

360-2 109V RMS, 360 Hz nominal settings

109V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-360-2

360-3 117V RMS, 360 Hz nominal settings

117V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-360-3

600-1 115V RMS, 600 Hz nominal settings

115V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-600-1

600-2 109V RMS, 600 Hz nominal settings

109V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-600-2

600-3 117V RMS, 600 Hz nominal settings

117V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-600-3

800-1 115V RMS, 800 Hz nominal settings

115V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-800-1

800-2 109V RMS, 800 Hz nominal settings

109V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-800-2

800-3 117V RMS, 800 Hz nominal settings

117V RMS, 2.5V RMS mod

Apply for 10+ mins

FTVF104-800-3

TVF105

Frequency Modulation

400-1 115V RMS, 400 Hz nominal settings

400 Hz, 4 Hz mod

Apply for 30+ mins

FTVF105-400-1

360-1 115V RMS, 360 Hz nominal settings

360 Hz, 4 Hz mod

Apply for 30+ mins

FTVF105-360-1

600-1 115V RMS, 600 Hz nominal settings

600 Hz, 4 Hz mod

Apply for 30+ mins

FTVF105-600-1