Test No. Section

Subject

Test Limits

Comment

File Ref.

TVF301

Abnormal Steady State Limits for Voltage and Frequency

100V to 125V RMS, 360Hz to 800
Hz

Apply for 30 mins

FTVF301

TVF302

Abnormal Voltage Transients

400-1 400 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table TVF302-2 A-G

FTVF302-400-1

400-2 400 Hz, Undervoltage Transients

Low Voltage 45V RMS

Table TVF302-2 H-N

FTVF302-400-2

400-3 400 Hz, Combined Transient

45V RMS to 180V RMS

Table TVF302-2 O

FTVF302-400-3

360-1 360 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table TVF302-2 A-G

FTVF302-360-1

360-2 360 Hz, Undervoltage Transients

Low Voltage 45V RMS

Table TVF302-2 H-N

FTVF302-360-2

360-3 360 Hz, Combined Transient

45V RMS to 180V RMS

Table TVF302-2 O

FTVF302-360-3

600-1 600 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table TVF302-2 A-G

FTVF302-600-1

600-2 600 Hz, Undervoltage Transients

Low Voltage 45V RMS

Table TVF302-2 H-N

FTVF302-600-2

600-3 600 Hz, Combined Transient

45V RMS to 180V RMS

Table TVF302-2 O

FTVF302-600-3

800-1 800 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table TVF302-2 A-G

FTVF302-800-1

800-2 800 Hz, Undervoltage Transients

Low Voltage 45V RMS

Table TVF302-2 H-N

FTVF302-800-2

800-3 800 Hz, Combined Transient

45V RMS to 180V RMS

Table TVF302-2 O

FTVF302-800-3

TVF303

Abnormal Frequency Transients

1

Overfrequency Transients

High Frequency 800 Hz

Table TVF303-2 A-D

FTVF303-1

2

Underfrequency Transients

Low Frequency 360 Hz

Table TVF303-2 E-H

FTVF303-2

3

Combined Transient

360 Hz to 800 Hz

Table TVF303-2 I

FTVF303-3

TVF401

Emergency Limits for Voltage and Frequency

Perform Test TVF102

TVF501

No Tests

N/A to AC Utilization Equipment

TVF601

Power Failure (Single Phase)

400-1 115V RMS, 400 Hz nominal settings

0V for 7 seconds

Table TVF601-2

FTVF601-400-1

360-1 115V RMS, 360 Hz nominal settings

0V for 7 seconds

Table TVF601-2

FTVF601-360-1

600-1 115V RMS, 600 Hz nominal settings

0V for 7 seconds

Table TVF601-2

FTVF601-600-1

800-1 115V RMS, 800 Hz nominal settings

0V for 7 seconds

Table TVF601-2

FTVF601-800-1

TVF602

One Phase and Two Phase Power Failures

400-1 One Phase Power Failures

0V for 7 seconds

Table TVF602-2 A-F

FTVF602-400-1

400-2 Two Phase Power Failures

0V for 30 mins

Table TVF602-2 G-J

FTVF602-400-2

360-1 One Phase Power Failures

0V for 7 seconds

Table TVF602-2 A-F

FTVF602-360-1

360-2 Two Phase Power Failures

0V for 30 mins

Table TVF602-2 G-J

FTVF602-360-2

600-1 One Phase Power Failures

0V for 7 seconds

Table TVF602-2 A-F

FTVF602-600-1

600-2 Two Phase Power Failures

0V for 30 mins

Table TVF602-2 G-J

FTVF602-600-2

800-1 One Phase Power Failures

0V for 7 seconds

Table TVF602-2 A-F

FTVF602-800-1

800-2 Two Phase Power Failures

0V for 30 mins

Table TVF602-2 G-J

FTVF602-800-2

TVF603

Phase Reversal

Phase reversal done physically FTVF603

Table SXF:

Test No. Section

Subject

Test Limits

Comment

File Ref.

SXF101

Load and Current Harmonic Measurements

115V RMS, 60 Hz

FSXF101

SXF102

Steady State Limits for Voltage and Frequency

105V to 125V RMS, 59.75 to 60.25 Hz

Apply for 30 mins each test

FSXF102

SXF103

No Test, Done so test numbers coincide