beautypg.com

AMETEK i Series User Manual

Page 202

background image

User Manual

188

i Series / iX Series

9.3.4 Front Panel Entry

While it is possible to perform IEC 61000-4-13 testing from the front panel of the iX Series AC
power source, it is recommended to use the provided Cigui32 Windows program for report
generation. This also provides a more convenient way to perform Class 1 and User class tests
as test levels can be saved to disk.

To perform a test from the keyboard, select the APPLICATIONS screen from the MENU 2
screen. The APPLICATIONS screen will appear as shown in Figure 9-24.

Figure 9-24: Application menu

Scroll to the IEC 61000-4-13 entry using the up and down cursor keys. Press the ENTER key to
select the IEC 61000-4-13 main menu. The screen will appear as shown in Figure 9-25.

Figure 9-25: IEC 61000-4-13 Menu

9.3.4.1 IEC 61000-4-13 Screen Parameters

The IEC 61000-4-13 screen has the following common fields for all IEC 61000-4-13 test groups.

STATE

The STATE field must be set to ON before the test can run. Initial setup conditions must be met
to run the test.

RUN

The RUN field has the following selections:

1. ALL

Run all IEC 61000-4-13.

2. GROUP

Run the selected group.

3. RANGE

Run the selected range for the selected group.

4. POINT

Run the selected frequency for the selected range and selected group.

Note: The RANGE and POINT do not apply to all groups. See individual groups for details.

When the test is running, this field will have the following selection:

1. ABORT

The test will stop running and all parameters will return to the state prior to the

start of the test.

2. PAUSE

The test will pause at the time the ENTER key is pressed while the PAUSE field

is selected. The field will change to RESUME. When the ENTER key is

pressed again, the test will resume from the point it stopped.

This manual is related to the following products: