AMETEK i Series User Manual
Page 214

User Manual
200
i Series / iX Series
9.4.4 Specifications
9.4.4.1 Input
Line Voltage
(user configurable)
115 VAC ±10%
230 VAC ±10%
Line Current
< 0.4 amps at 115 VAC input
< 0.2 amps at 230 VAC input
Line Frequency
47 to 63 Hz
Fuse Rating
0.5 amp, slow acting at 115 VAC input
0.25 amp, slow acting at 230 VAC input
9.4.4.2 Output
EOS-1
EOS-3
Phases
1
3
IEC 1000-4-11 Test Mode Engaged:
Voltage
Range
100-270 V
RMS
Regulation
<5%, 100% output
< 7%, 80% output (EOS Gen 2 only)
<7%, 70% output
<10%, 40% output
Over/Undershoot
<5% into a 100 ohm resistive load
Rise/Fall Times
Between 1 s & 5 s into a 100 ohm resistive load
measured from 10% to 90% of transition
Programmable Output Levels
100%, 70%, 40%, and 0% of U
NOM
Frequency
Range
50 Hz/60 Hz
Accuracy
+/- 0.02%
Phase
Range
0.0 - 360
Accuracy
+/- 1.0
Maximum Current
at 100% U
NOM
18.5 A
RMS
18.5 A
RMS
/phase
at 80% U
NOM
(EOS Gen 2 only)
26.4 A
RMS
26.4 A
RMS
/phase
at 70% U
NOM
23.1 A
RMS
23.1 A
RMS
/phase
at 40% U
NOM
46.2 A
RMS
46.2 A
RMS
/phase
Maximum Peak Current
92.5 A
92.5 A/ phase