beautypg.com

AMETEK i Series User Manual

Page 185

background image

User Manual

i Series / iX Series

171

16.5.2.1c

3 Phs Voltage (ac)

97V to 134V, 360Hz

Apply for 5 mins each test

EAWF115_VABN3P360

16.5.2.1c

3 Phs Voltage (ac)

97V to 134V, 800Hz

Apply for 5 mins each test

EAWF115_VABN3P800

16.5.2.2

Momentary Undervoltage (ac)

10V and 60V, 360Hz

Apply for 7 seconds each test

EAWF115_VUND360

16.5.2.2

Momentary Undervoltage (ac)

10V and 60V, 800Hz

Apply for 7 seconds each test

EAWF115_VUND800

16.5.2.3

Abnormal Transients (ac)

16.5.2.3.1 - Abnormal Voltage surge

148V to 180V, 360Hz

Figure 16.5 - apply at 10 sec intervals EAWF115_AVSUR360

16.5.2.3.1 - Abnormal Voltage surge

148V to 180V, 800Hz

Figure 16.5 - apply at 10 sec intervals EAWF115_AVSUR800

This manual is related to the following products: