AMETEK i Series User Manual
Page 278
User Manual
264
i Series / iX Series
9.8.2.10 704 EUT Performance Measurements
Figure 9-65: 704 Option EUT Measurement Data Screen.
The EUT Performance Measurements tab in the 704 tests window provides measurement data
taken by the power source‟s data acquisition system. This tab contains four sub-tabs that each
present different aspects of the EUT measurement data. Additional user controls for
measurement updates and graph scaling are provided right next to the four sub tabs. The
following sub tabs are available for selection.
Sub-Tab
Description
Parameters
This tab displays the parametric measurement data in tabular form. This includes
voltage, current, power, power factor, distortion etc. For three-
phase EUT‟s data is
shown for all three phases. For single phase EUT, data is shown for phase A only
as long as the power source is in single-phase mode.
The top half of the Parameters tab displays all parametric measurement data. The
following data is available:
Volt RMS (V)
Displays source voltage per phase in Volt RMS or DC
depending on power source mode of operation.
Curr RMS (A)
Displays EUT current per phase in amps RMS or DC
depending on power source mode of operation.
App. Power (VA)
Displays the apparent power for each phase as well as the
total power for all three phases.
For three-
phase EUT‟s, any imbalance in power between the
three phases is calculated by the GUI program and compared
against Figure 11 of the MIL-STD-704A or Figure 1 of the