EXFO RTU 310-310G IP Services Test Head User Manual

Page 414

background image

System Tabs

402

RTU-310/310G

Clock Synchronization

Frequency: The Frequency alarm indicates if the received signal rate
meets (green) or not (red) the following rate specifications.

Frequency Analysis

Frequency (bps) displays the received DS1/2M/E1signal rate in bps.

Frequency Offset displays the positive or negative frequency offset
between the standard rate specification and the rate from the received
signal. Frequency unit can be set to bps, or ppm. The default setting is
bps.

Note: The frequency value displays “>50” when the frequency offset is bigger

than ±50 ppm.

Signal

Rate specification

DS1

1544000 ±15 bps (±9.2 ppm)

E1

2048000 ±19 bps (±9.2 ppm)

2MHz

2048000 ±19 Hz (±9.2 ppm)