beautypg.com

Frame loss (rfc 2544) – EXFO RTU 310-310G IP Services Test Head User Manual

Page 382

background image

Expert Mode Tabs

370

FTB-8500 Series and FTB-8120NGE/8130NGE

Frame Loss (RFC 2544)

Frame Loss (RFC 2544)

Click TEST, Expert Mode, and Frame Loss.

Enable Criteria: Allows to enable Frame Loss Pass/Fail criteria. This
setting is disabled by default.

Note: Both Enable Criteria and the test itself (see Global Configuration on

page 296) have to be enabled for a specific test to be able to change its
criteria values.

Frame Size: Indicates the frame sizes selected for the test.

TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local:

For each frame size, enter the maximum percentage of frames that can
be lost before declaring a Fail condition.

Status: Indicates the real-time pass/fail condition.

Grey LED: Indicates that Expert Mode is disabled or the test did not
run yet.
Green LED: Indicates that the threshold is respected (Pass).
Red LED: Indicates that the threshold is not respected (Fail).

Copy From Measurement button: Copy the performance results from
the test that ran previously and use it as the Pass/Fail criteria. If no test
ran before, default values used will be 0% Loss.

Unit: Unit is set to % Loss frames.