beautypg.com

EXFO RTU 310-310G IP Services Test Head User Manual

Page 203

background image

Stream Generation Tabs

Ethernet and Fibre Channel Application

191

Frame Configuration (Fibre Channel)

CS_CTL: The Class Specific Control field contains management
information for the class of service identified by the SOF. The default
setting is hexadecimal 00 corresponding to no preference and no
specific DSCP. Possible values for Class 3 service are:

S_ID: The source identifier specifies the source port address. Choices
are listed in the D_ID table. Refer to D_ID for more information. The
default setting is hexadecimal 000000.

Note: The source identifier address may be affected by the login process.

TYPE: The Data Structure Type indicates the type of data contained in
the data field. The default value is FF corresponding to Vendor specific.

Bit

Description

31

PREF (Preference)

0 = Frame is delivered with no Preference

1 = Frame may be delivered with Preference

30

Reserved for additional Preference function

29-24

DSCP (Differentiated Services Code Point)