Test status – EXFO RTU 310-310G IP Services Test Head User Manual
Page 134
Summary Tabs
122
FTB-8500 Series and FTB-8120NGE/8130NGE
Test Summary
Test Status
Start Time: Indicates the date and time the test has been started. The
date and time reset every time the test is restarted. The default time
format is ISO (yyyy-mm-dd hh:mm:ss) unless otherwise set from the
Application Preferences on page 334.
Port Link: Indicates the link status at the input port of the
Ethernet/Fibre Channel interface. A green LED indicates that the link is
up while a grey LED indicates a link down.
Expert Mode Verdict: Indicates the status of the expert mode. This
information is only available with RFC 2544 and BERT Ethernet tests.
Pass is declared if all results values meet the configured criteria.
Fail is declared if any result value does not meet the configured
criteria.
-- is displayed when at least one of the following conditions is met:
- the Expert Mode is disabled.
- there is no defined criterion.
- for RFC 2544 test, when the specific test did not run yet.
- for BERT test, when the test is still running or didn’t run yet.
Disabled is displayed with RFC 2544 test when a specific test
(Throughput, Back-to-Back, Frame Loss, or Lantency) has its Expert
mode’s Enable Criteria check box cleared.
Global Verdict for EtherSAM test: Indicates the actual test PASS or
FAIL verdict. A FAIL verdict is declared when a Link Down, LOS, or any
SLA parameter fails during the test.