Creating and Starting a Test Case

88

FTB-8500 Series and FTB-8120NGE/8130NGE

Ethernet EtherSAM (Y.1564) and RFC 2544 Dual Test Set Test Cases

2. For additional configuration parameters, refer to EtherSAM Tabs on

page 321 or RFC 2544 Tabs on page 295.

3. On the local module, click the Start button to start the test. The Start

button will be available only when the connection between the two
RTU-310/310G units is established.

At least one of the test procedures (For EtherSAM (Y.1564): Service
Configuration Test
or Service Performance Test; For RFC 2544:
Throughput, Back-to-Back, Frame Loss or Latency) has to be enabled
to start the test. Test procedures that are enabled will be performed
following this order:
Service Configuration Test and Service Performance Test for
EtherSAM (Y.1564)
Throughput
, Back-to-Back, Frame Loss, and Latency for RFC 2544.

4. For additional results, refer to EtherSAM Tabs on page 321 or RFC 2544

Tabs on page 295.