Creating and Starting a Test Case

114

FTB-8500 Series and FTB-8120NGE/8130NGE

Ethernet TCP Throughput Test Case

2. Port configuration:

Port 1 (RTU-310 only) is automatically selected.

2a. Select the port Connector

Type (Optical or
Electrical RJ-45). Optical is automatically selected for the
Ethernet 10G interface.

2b. For Electrical RJ-45, if required, select

the Ethernet port crossover check box
to inverse the pin-to-pair assignment of
the UTP cable used.

Note: At this point you should have a link up indicated in the Tree view tab. A

green LED indicates a link up while a red LED indicates a link down. For
electrical port, if the link is down, make sure that the Ethernet port
crossover
setting is correct.

2c. Click Next.

3. Framing configuration:

3a. Set the Auto-Negotiation, Speed,

Duplex, and Flow Control parameters.
Refer to Interface Setup (Ethernet) on
page 142 for more
information.

3b. Select the Frame Format. Choices are

Ethernet II and 802.3 SNAP. Refer to
Network on page 150 for more
information.

3c. Set the IP Address (IPv4), Automatic IP

address, Subnet Mask, and Default
Gateway
parameters. Refer to Source IP Configuration on
page 152 for more
information.

3d. Click Finish to complete the test setup. The Alarm summary tab

is automatically displayed.