Buffer-to-buffer flow control, World wide name – EXFO RTU 310-310G IP Services Test Head User Manual
Page 161
Port Tabs
Ethernet and Fibre Channel Application
149
Interface Setup (Fibre Channel)
Buffer-to-Buffer Flow Control
Enable: The Enable check box is forced selected when Login is
selected. The RTU-310/310G will send a Received Ready (R_RDY)
automatically after receiving a frame when the Enable check box is
selected.
Note: Since R_RDY are inserted between frames and have higher priority, in
certain condition they may affect the TX throughput.
Available BB_Credit is the number of frame buffers that the remote
port has available to receive frames from the local port. Available
BB_Credit is not editable when either the Enable or Enable login
check box is selected. Choices are from 1 to 65535. The default setting
is 10.
Note: After a Login process, the Available BB_Credit displays the value received
from the remote interface through the login process.
World Wide Name
Only available when Enable Login is enabled.
Source: Enter the World Wide Name source address.
Destination: The destination Worldwide Name will be displayed and
grayed-out after the Login process when Point-to-Point is selected.
Enter the Worldwide name destination address.