beautypg.com

Tcp mode, Tcp connection configuration – EXFO RTU 310-310G IP Services Test Head User Manual

Page 362

background image

TCP Throughput Tabs

350

FTB-8500 Series and FTB-8120NGE/8130NGE

TCP Throughput Configuration

Click TEST, TCP Throughput, and TCP Throughput Configuration.

TCP Mode

Since two units are required to perform a TCP Throughput test, one unit
must be the source (Local) unit and the other one the destination
(Remote). Set the TCP Mode on both units. Choices are Local and Remote.
The default setting is Local.

TCP Connection Configuration

Remote IP Address (Available with Local TCP Mode): On the local
unit, enter the IP Address of the remote unit.

Listening IP Address (Available with Remote TCP Mode): On the
remote unit, enter the IP Address of the local unit. The IP address
0.0.0.0 can be used to listen to any TCP stream. The default setting is
0.0.0.0.