RFC 2544 Tabs
Ethernet and Fibre Channel Application
313
Latency
Configuration
Test Time (MM:SS): Select the test time value. Choices are 1 second to
2 minutes (RFC). The default setting is 1 second (00:01).
Nb. of Trials to Average: Select the number of trials to average.
Choices are from 1 to 50 trials. The default setting is 1 trial.
Minimum Test Time (Seconds): Indicates the minimum time the test
requires to run at best condition. The minimum test time is calculated
and updated once the test is started.
Maximum Rate: The maximum rate can be entered manually by typing
the value for each frame size in the TX-to-RX/P1-to-P2/P2-to-P1/Local
to Remote/Remote to Local column or using the Set All to, or by
enabling the Copy From Throughput Test. P1-to-P2/P2-to-P1 is only
available with RTU-310.
TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local:
Enter the value for each frame size. Choices are listed in the
following table. The default setting is 100%. P1-to-P2/P2-to-P1 is
only available with RTU-310.
Unit
Interface
Rate
from
to
%
10 Mbps
100 Mbps
1000 Mbps
10 Gig-E LAN
10 Gig-E WAN
0.005
0.005
0.005
0.005
0.005
100
100
100
100.0
92.8571428571429
Mbps
10 Mbps
100 Mbps
1000 Mbps
0.0005
0.005
0.05
10
100
1000
Gbps
10Gig-E LAN
10Gig-E WAN
0.0005
0.0005
10.0