beautypg.com

Configuration – EXFO RTU 310-310G IP Services Test Head User Manual

Page 325

background image

RFC 2544 Tabs

Ethernet and Fibre Channel Application

313

Latency

Configuration

Test Time (MM:SS): Select the test time value. Choices are 1 second to
2 minutes (RFC). The default setting is 1 second (00:01).

Nb. of Trials to Average: Select the number of trials to average.
Choices are from 1 to 50 trials. The default setting is 1 trial.

Minimum Test Time (Seconds): Indicates the minimum time the test
requires to run at best condition. The minimum test time is calculated
and updated once the test is started.

Maximum Rate: The maximum rate can be entered manually by typing
the value for each frame size in the TX-to-RX/P1-to-P2/P2-to-P1/Local
to Remote
/Remote to Local column or using the Set All to, or by
enabling the Copy From Throughput Test. P1-to-P2/P2-to-P1 is only
available with RTU-310.

TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local:
Enter the value for each frame size. Choices are listed in the
following table. The default setting is 100%. P1-to-P2/P2-to-P1 is
only available with RTU-310.

Unit

Interface

Rate

from

to

%

10 Mbps

100 Mbps

1000 Mbps

10 Gig-E LAN

10 Gig-E WAN

0.005
0.005
0.005
0.005
0.005

100
100
100
100.0
92.8571428571429

Mbps

10 Mbps

100 Mbps

1000 Mbps

0.0005
0.005
0.05

10
100
1000

Gbps

10Gig-E LAN

10Gig-E WAN

0.0005
0.0005

10.0
9.2857142857142865