Ethernet rx, Configuration, Alarms analysis – EXFO RTU 310-310G IP Services Test Head User Manual

Page 215

background image

Traffic Analyzer Tabs

Ethernet and Fibre Channel Application

203

Ethernet RX

Ethernet RX

Click TEST, Traffic Analyzer, and Eth. RX.

Configuration

Oversize Monitoring

Enables the monitoring of the Oversize error.

Alarms Analysis

Link Down: Indicates that the Ethernet connection is down. The
Ethernet connection is down when there is a local or a remote fault
condition.

Local Fault (10Gig-E): Indicates that at least one of the following
events is detected: LOS, Loss of bit synchronization, Loss of Block
synchronization
, WIS Link down, or High BER (High BER is true
when the bit error ratio > 10

-4

on a fixed 125 μs time period).

Remote Fault (10Gig-E): Indicates that a Remote Fault event is
detected.

Note: Alarms/Errors are updated only during test execution.