beautypg.com

EXFO RTU 310-310G IP Services Test Head User Manual

Page 373

background image

Common Tab

Ethernet and Fibre Channel Application

361

Performance Monitoring (PM)

SES (Severely Errored Second)

For G.821: Gives the number of seconds within which a bit error ratio
is  10

-3

, or during which Loss Of Signal (LOS), Link down, or Pattern

Loss is detected.

For G.826: Gives the number of seconds within which EB count is 
SES threshold (30%), or at least one NE defect occurred.

BBE (Background Block Error) (G.826 only): Gives the count of Errored
Block not occurring as part of a SES. A Block corresponds to a
complete Ethernet/Fibre Channel frame.

AS (Available Second): Gives the count of the seconds corresponding
to the periods of time within which no SES errors occurred for at least
10 consecutive seconds.