Interface configuration – EXFO RTU 310-310G IP Services Test Head User Manual
Page 397
System Tabs
Ethernet Test Module
385
Default/Ethernet Test Preferences
Interface Configuration
Note: The following interface configuration parameters are available for both
ports (RTU-310) and apply only to IPv4 at the exception of Sequence Tag in
TX that also apply to IPv6.
Auto-Negotiation: The Auto-Negotiation check box should be
selected if the connected switch is also set to Auto-Negotiation,
otherwise the Auto-Negotiation check box should be cleared.
When selected, the RTU-310/310G will indicate to the switch which
parameters to use. The Auto-negotiation check box is selected by
default. Available with 10/100/1000Mbps interfaces.
Sequence Tag in TX, available with Frame Analyzer test on
RTU-310 and RTU-310G only, automatically adds a sequence tag in
all frames that will be generated. The Sequence Tag in TX check
box is selected by default.
IP Address: Enter the IP address for the Ethernet port. The factory
IP address is 10.10.x.y, where x and y are respectively the two least
significant bytes of the port default MAC address.
Automatic IP Address: Automatically selects DHCP when a test is
created allowing to dynamically obtain an IP address from a DHCP
server. The Automatic IP Address check box is cleared by default.
Subnet Mask: Enter the subnet mask for the Ethernet port. The
default setting is 255.255.0.0.
Default Gateway: Enter the default getaway address for the
Ethernet port. Default Gateway must be enabled to enable the
default gateway address field. The default setting is 0.0.0.0.
Enable: Enables the default gateway IP address. The Enable check
box is not selected by default.