Results – EXFO RTU 310-310G IP Services Test Head User Manual
Page 318
RFC 2544 Tabs
306
FTB-8500 Series and FTB-8120NGE/8130NGE
Back-to-Back
Results
Test State
--: Indicates that the test has not run yet.
In Progress: Indicates that the test is running.
Completed: Indicates that the test is completed.
Aborted: Indicates that the test has been interrupted (stopped).
Status Message: Gives the test status. Following is the list of status
messages.
Sending learning frames
Sending test frames
Test completed
Aborted by user
Aborted - Loss of remote connection
Link down
MAC address not resolved
Frames Count
TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local: Gives
the number of frames for the indicated direction. P1-to-P2/P2-to-P1 is
only available with RTU-310.
TX Frame Count: Indicates the number of transmitted frames.
RX Frame Count: Indicates the number of received frames.
Back-to-Back Results
Frame Size: Indicates the frame sizes used for the test. Up to seven
different frame sizes can be displayed.
Note: The “--” indicates that the result is not available because the test has not
run yet or the measured value is not valid.
TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local:
Gives the number of frames for the corresponding direction.
P1-to-P2/P2-to-P1 is only available with RTU-310.