Burst (configuration), Burst sequence – EXFO RTU 310-310G IP Services Test Head User Manual

Page 347

background image

EtherSAM Tabs

Ethernet and Fibre Channel Application

335

Burst (Configuration)

Burst (Configuration)

Note: The Burst configuration is only available when the burst test is enabled (see

Burst Test on page 324).

Click TEST, EtherSAM Configuration, and Burst.

Note: The burst template is defined globally for all services but CBS, EBS, and

Burst Max Rate parameters are as per each Services configuration. For
example, a stream may be configured to perform the CBS test, another one
to perform the EBS test, and another one to perform both CBS and EBS
tests.

Burst Sequence

The graphic illustrates the configured burst sequence. The sequence
contains in order, from left to right:

Refill Delay represents the pre-burst recuperation time in percentage
that is equal to the remaining percentage not used by the post-burt
time (Refill Delay Ratio).