Port Tabs

Ethernet and Fibre Channel Application

159

Advanced Auto-Neg. RX

Advanced Auto-Neg. RX

Note: Advanced auto-negotiation is not available with the optical 100 Mbps and

10 Gig-E interfaces.

Click TEST, Port1/2, and Advanced Auto-Neg RX.

Status

Link: A green Link LED indicates that there is a link at the input port of
the corresponding Ethernet interface. A red LED indicates that there is
no link at the input port of the corresponding Ethernet interface.

Auto-Negotiation: Indicates the auto-negotiation status. Possible
values are:

Negotiating: indicates that the auto-negotiation process is running and
not completed yet.

Completed: indicates that the auto-negotiation process has completed
successfully.

Parallel Detect Fail: indicates that auto-negotiation has failed through
the parallel detection process while negotiating in 10/100Base-T.

Remote Fault: Indicates the remote fault error. Possible values are
Error-Offline (1000Base-X only) , Error-Link Fault (1000Base-X only),
and Error-Auto-Negotiation error.

Speed: Indicates the negotiated speed. Possible values are 10, 100,
and 1000.