beautypg.com

Standard, Statistics – EXFO RTU 310-310G IP Services Test Head User Manual

Page 372

background image

Common Tab

360

FTB-8500 Series and FTB-8120NGE/8130NGE

Performance Monitoring (PM)

Standard

Select the desired standard from the list. Choices are:

Statistics

EFS (Error Free Second): Gives the number of seconds within which
no bit error occurred.

EC (Error Count) (G.821 only): Gives the number of bit errors.

EB (Errored Block) (G.826 only): Gives the count of blocks (frame) in
which one or more bits are in error.

ES (Errored Second):

For G.821: Gives the number of seconds within which one or more bit
error occurred, or during which Loss Of Signal (LOS) or Link down is
detected.

For G.826: Gives the number of seconds within which one or more
Errored Block (EB) occurred, or at least one NE defect occurred.

Standard

Framed

Layer 2

Framed

Layer 1

Unframed

Traffic Analyzer

G.826 ISM

X

X

a

a. Available with xPAT test pattern only. xPAT patterns are available with

BERT 1000Mbps optical test using Framed Layer 1.

G.826 OOSM

X

X

Pattern

G.821

X

X

X