Sla parameters – EXFO RTU 310-310G IP Services Test Head User Manual
Page 341
EtherSAM Tabs
Ethernet and Fibre Channel Application
329
Services (Configuration)
PBB-TE indicates and allows to change the selected frame PBB-TE
destination address. PBB-TE is only displayed when PBB-TE has been
enabled. Refer to PBB-TE Interface configuration on page 487 for more
information.
MPLS indicates and allows to change the selected frame label. MPLS is
only displayed when MPLS has been enabled. Refer to MPLS
Configuration on page 503 for more information.
UDP indicates and allows to change the selected source and
destination UDP ports. UDP is only available when the Framing’s
Transport is set to UDP. Refer to UDP Configuration on page 505 for
more information.
TCP indicates and allows to change the selected source and
destination TCP ports. TCP is only available when the Framing’s
Transport is set to TCP. Refer to TCP Configuration on page 505 for
more information.
IP TOS indicates and allows to change the selected frame IP TOS
settings. Refer to Advanced TOS/DS on page 506 for more information.
SLA Parameters
The SLA (Service-Level Agreement) parameters allows defining the
pass/fail verdict thresholds for the service. Use the check boxes to enable
the pass/fail verdict for these parameters and enter the threshold values.
Information Rate
Note: At least one check box (CIR or CIR+EIR) has to be selected. Thus, clearing
the CIR check box while CIR+EIR check box is cleared, will automatically
select the CIR+EIR check box and vice versa.
CIR (Committed Information Rate) sets the service rate guaranteed by
the SLA. The CIR check box is selected by default and its value sets to
50% of the line rate. CIR and preceding steps are not performed for
services that have the CIR check box cleared.