Auto-discovery – EXFO RTU 310-310G IP Services Test Head User Manual
Page 265
IPTV Tabs
Ethernet and Fibre Channel Application
253
Discovery
The status of each stream, active or inactive, is visually presented as follow:
Active: Streams on which MPEG-2 TS data is currently being received.
Active streams are listed using black characters.
Inactive: Streams that are no longer receiving MPEG-2 TS data. Inactive
streams are listed using grey characters.
Monitored streams are streams that have been added for IPTV monitoring
in the overview page. Monitored streams are highlighted with a light blue
background.
Selected streams are highlighted with a dark blue background.
Auto-Discovery
On/Off button: Scans the network test point to automatically identify
IPTV and/or VoD streams that conform to the MPEG-2 transport stream
format. Newly detected streams are appended to the discovery list.
This setting is Off by default. Turning Auto-Discovery Off and On will
not clear the previously discovered streams. The discovery process is
independent from the test case start/stop status or the Reset function.
Clear List button: Resets the list of discovered streams. If the
Auto-Discovery is On, after clicking Clear List, the discovery list is
refreshed. The clear operation doesn’t affect the streams that are
monitored.
Hide monitored Streams: Filters out all the monitored streams from
the discovered stream list. This option is selected by default.