Latency (rfc 2544) – EXFO RTU 310-310G IP Services Test Head User Manual
Page 384
Expert Mode Tabs
372
FTB-8500 Series and FTB-8120NGE/8130NGE
Latency (RFC 2544)
Latency (RFC 2544)
Click TEST, Expert Mode, and Latency.
Enable Criteria: Allows to enable Latency Pass/Fail criteria. This
setting is disabled by default.
Note: Both Enable Criteria and the test itself (see Global Configuration on
page 296) have to be enabled for a specific test to be able to change its
criteria values.
Frame Size: Indicates the frame sizes selected for the test.
TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local:
For each frame size, enter the maximum time required for the sent
frame to come back before declaring a Fail condition.
P1-to-P2/P2-to-P1 is only available with RTU-310.
Status: Indicates the real-time pass/fail condition.
Grey LED: Indicates that Expert Mode is disabled or the test did not
run yet.
Green LED: Indicates that the threshold is respected (Pass).
Red LED: Indicates that the threshold is not respected (Fail).
Copy From Measurement button: Copy the performance result
minimum values from the test that ran previously and use it as the
Pass/Fail criteria. If no test ran before, default values used will be
0.015 ms with Store and Forward mode.
Unit: Select the unit. Choices are s, ms, μs, and ns. The default setting
is ms.