beautypg.com

Auto-neg. fault register, Local capabilities – EXFO RTU 310-310G IP Services Test Head User Manual

Page 169

background image

Port Tabs

Ethernet and Fibre Channel Application

157

Advanced Auto-Neg. TX

Auto-Neg. Fault Register

Fault Type: Allows the generation of a fault during the negotiation
process. Changing the fault type, while enabled, will automatically
restart the negotiation process. The fault condition will be generated
only once when clicking on the Negotiate button. The default setting is
No Error. Choices are:

For electrical port: No Error and Auto-Negotiation Error.

For 1000Mbps optical port: No Error, Off-line, Link Failure, and
Auto-Negotiation Error.

Local Capabilities

Allows enabling the local port capabilities by checking all supported
predefined speed, duplex and flow control combination. This setting is
disabled by default.

Note: The available port capabilities are based on the physical port selected for

the test, which is either electrical or optical.

Local Capabilities

When the local capabilities is enabled, select the supported port
capabilities. Local capabilities are disabled by default. Choices are:

10Base-T, Half Duplex
10Base-T, Full Duplex
100Base-TX, Half Duplex
100Base-TX, Full Duplex
1000Base-T, Full Duplex
1000Base-X, Full Duplex
Symmetric Pause
Asymmetric Pause