Configuration – EXFO RTU 310-310G IP Services Test Head User Manual
Page 368
Advanced Tab
356
FTB-8500 Series and FTB-8120NGE/8130NGE
Service Disruption Time (SDT)
Configuration
Select the criteria that will be used for the SDT measurement.
Note: The service disruption measurements are cleared when changing the
criteria.
Measurement Mode: Select the SDT measurement mode. Choices are
Defect Mode and No Traffic Mode. The default setting is Defect Mode.
Defect Mode is based on the detection of defects including LOS, Link
down, Invalid FCS, LSS, and Bit errors in the payload. The SDT
measurement is the time between the first defect and either the end of
the last defect preceding the No Defect Time period, or the end of the
test period.
No Traffic Mode is based on the absence of traffic. The SDT
measurement is the time between the end of the last received frame
and either the beginning of a new received frame, or the end of the test
period.
No Traffic Time: Available for No Traffic Mode only. No Traffic Time is
a configured value which raises a defect if no Ethernet frame is
received during the defined test period. Choices are:
Unit choices are μs, ms, and s. The default setting is 10000 μs.
No Defect Time: Available for Defect Mode only. No Defect Time
represents the period without any defects before stopping SDT
measurement. Choices are from 20 to 99990 μs for 10/100/1000Mbps
and 10 to 99000 μs for 10Gbps The maximum value is adjusted with
respect to the test period (the max No Defect Time is obtained when
Rate
No Traffic Time range
10/100/1000Mbps 10 to 99990 μs for RTU-310
10Gbps
10 to 100000 μs for RTU-310G