beautypg.com

Configuration – EXFO RTU 310-310G IP Services Test Head User Manual

Page 167

background image

Port Tabs

Ethernet and Fibre Channel Application

155

Advanced Auto-Neg. TX

Configuration

The Speed, Duplex, and Flow Control can be modified only when the
Enable Local Capabilities is disabled.

Speed: Select the speed of the connected interface. Choices are:

For electrical port: 10Mbps, 100Mbps, 1Gbps, and Auto.

For optical port: 1Gbps.

Duplex: Select the duplex mode for the selected port. Choices are:

For 10 Mbps and 100 Mbps speeds (except for BERT and Smart
Loopback
tests): Full, Half, and Auto.

For 1Gbps speed, BERT or Smart Loopback: Full.

Flow Control: Select the flow control of the connected interface. The
default setting is None. Choices are:

None: Pause frame received are ignored and no pause frame are
transmitted. None is the only choice for BERT and Smart Loopback
tests.

Asymmetrical: Pause frame can be transmitted but not received.

Symmetrical: Pause frame can be received and transmitted depending
on the link partner (L. P.) flow type (see table below).

Asym. and Sym. (Asymmetrical and Symmetrical): pause frame can be
received and/or transmitted depending on the link partner (L. P.) flow
type (see table below).

Auto: Allows the negotiation of the flow control with the partner port.