Table 26 summarizes the results of the immunity and RF testing for a typical L
ON
W
ORKS
application based on an FT 6000 Smart Transceiver with the FT-X3 Communications
Transformer. EMC testing results for the Neuron 6000 Processor depend on the specific
network transceiver used.
Table 26. Immunity and EMI Results
Test
FT 6000 Smart Transceiver with FT-X3 Communications
Transformer
EN 61000-4-2
ESD
15 kV Air
8 kV Contact
(Level 4)
EN 61000-4-3
Radiated RF
10 V/m
(Level 3)
EN 61000-4-4
Network Burst
2 kV
(Level 4)
EN 61000-4-5
Network Surge
2 kV or 6 kV
(depends on clamping diodes used; see Table 21)
(Level 3)
EN 61000-4-6
Conducted RF
10 V
RMS
(Level 3)
CISPR 22
Radiated EMI
Class B
CISPR 22
Conducted EMI
Class B