Summary and testing results – Echelon Series 6000 Chip databook User Manual

Page 101

background image

Summary and Testing Results

Table 26 summarizes the results of the immunity and RF testing for a typical L

ON

W

ORKS

application based on an FT 6000 Smart Transceiver with the FT-X3 Communications

Transformer. EMC testing results for the Neuron 6000 Processor depend on the specific

network transceiver used.

Table 26. Immunity and EMI Results

Test

FT 6000 Smart Transceiver with FT-X3 Communications

Transformer

EN 61000-4-2
ESD

15 kV Air
8 kV Contact
(Level 4)

EN 61000-4-3
Radiated RF

10 V/m
(Level 3)

EN 61000-4-4
Network Burst

2 kV
(Level 4)

EN 61000-4-5
Network Surge

2 kV or 6 kV

(depends on clamping diodes used; see Table 21)
(Level 3)

EN 61000-4-6
Conducted RF

10 V

RMS

(Level 3)

CISPR 22
Radiated EMI

Class B

CISPR 22
Conducted EMI

Class B




Series 6000 Chip Data Book