Input assemblies (address 21 or above) read data – KEYENCE SR-750 Series User Manual
Page 98
98
E SR-750 UM
Input Assemblies (Address 1, Bit 8 to Bit 15) Error status
* If any of the above errors occurs, the error code is output to "Failure cause status
(Input Assemblies address 8 to 16)".
Input Assemblies (Address 2, Bit 0 to Bit 6) Terminal status
* The above chart shows the contents when the input polarity setting of the SR-750
is Norm. open (normally open).
For Norm. closed (normally closed), the data is reversed as 0: ON 1: OFF.
* For assigning functions to terminals, refer to "3-6 Multi-I/O Function".
Input Assemblies (Address 2, Bit 8 to Bit 12) Judgment result
status for matching level and code quality verification function
* Use this status when the code quality verification function of SR-750 is enabled.
For the code quality verification function settings, refer to "3-11 Code quality
verification function".
Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
1
Address Bit
Name
Description
Data contents
1
8
Reading Error
This turns ON when reading error
or comparison NG occurs.
0 : -
1 : Reading error,
Comparison NG
*
1
9
Preset
Reading Failure
This turns ON when preset reading
fails.
0 : -
1 : Preset reading failure
*
1
10
Preset
Data
Registration
Failure
This turns ON when preset data
registration fails.
0 : -
1 : Preset data
registration failure
*
1
11
Tuning
Failure
This turns ON when tuning fails.
0 : -
1 : Tuning failure
*
1
15
External
Instruction
Operation
Failure
This turns ON when "Reading",
"Preset reading" or "Tuning" is
performed with the IN terminal or
command and the operation fails.
0 : -
1 : External instruction
operation failure
*
Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
2
Address Bit
Name
Description
Data contents
2
0
IN1 Status
This represents IN1 terminal
status.
0 : OFF
1 : ON
2
1
IN2 Status
This represents IN2 terminal
status.
0 : OFF
1 : ON
2
4
OUT1 Status
This represents OUT1 terminal
status.
0 : OFF
1 : ON
2
5
OUT2 Status
This represents OUT2 terminal
status.
0 : OFF
1 : ON
2
6
OUT3 Status
This represents OUT3 terminal
status.
0 : OFF
1 : ON
Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
2
Address Bit
Name
Description
Data contents
2
8
Unstable
This Bit turns ON when any of the
following Unstable Bits (9 to 12) is
ON.
0 : Stable
1 : Unstable
2
9
Matching Level
Unstable
Matching level judgment result
0 : Stable
1 : Unstable
2
10
ISO/IEC15415
Unstable
ISO/IEC15415 verification
judgment result
0 : Stable
1 : Unstable
2
11
AIM DPM
Unstable
ISO/IEC TR 29158 (AIM DPM-1-
2006) verification judgment result
0 : Stable
1 : Unstable
2
12
SAE AS9132
Unstable
SAE AS9132 Unstable verification
judgment result
0 : Stable
1 : Unstable
Input Assemblies (Address 4 to 6) Total evaluation grade
for matching level and code quality verification function
* Use this status when the code quality verification function of SR-750 is enabled.
For the code quality verification function settings, refer to "3-11 Code quality verification function".
Input Assemblies (Address 8 to 16) Failure cause status
For error codes, refer to List of error codes (Page 111).
Input Assemblies (Address 18 to 19) Read data status
* When the count number reaches 65535 and the next data arrives, the count number returns to 0.
Input Assemblies (Address 21 or above) Read data
* When the header, terminator and append data are set to the read data of SR-750, the header,
terminator, append data and inter-delimiter are also output. [CR] has been set to the
terminator as the default setting. Accordingly, [CR] is appended after the read data for output.
* If the silent mode is set for SR-750, read data is not output.
* [NUL]0x00 is appended to the end of result data.
Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
4
5
6
Address Bit
Name
Description
Data
contents
Data type
4
Matching Level
Matching Level
* If multiple codes are read, the
minimum value is output.
0 to 100
UINT
5
ISO/IEC15415
Grade
Total evaluation grade for ISO/
IEC15415 verification
4 : A
3 : B
2 : C
1 : D
0 : F
UINT
6
AIM DPM
Grade
Total evaluation grade for ISO/IEC
TR 29158 (AIM DPM-1-2006)
4 : A
3 : B
2 : C
1 : D
0 : F
UINT
Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
8
9
10
11
15
16
Address Bit
Name
Description
Data
contents
Data type
8
Reading Error
Cause
When any of the error statuses
(Input Assemblies Address 1, Bit 8
to Bit 15) turns on, the error code
is output to the applicable location.
Error code
*
UINT
9
Preset Reading
Failure Cause
UINT
10
Preset Data
Registration
Failure Cause
UINT
11
Tuning
Failure Cause
UINT
15
External Instruction
Operation
Error Cause
UINT
16
General Error
Cause
UINT
Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
18
19
Address Bit
Name
Description
Data
contents
Data type
18
Read Data
Ready Count
Read Data Ready Count
0 to 65535
*
UINT
19
Read Data
Update Count
Read Data Update Count
0 to 65535
*
UINT
Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
21
22
…
Address Bit
Name
Description
Data
contents
Data type
21
Read Data Size Read data length
0 and above
*
UINT
22 and
above
Read Data
Read Data
Read data
*
BYTE[]