Configuring the kv series, Melsec series configuration, Configuring the kv series rs-232c interface – KEYENCE SR-750 Series User Manual
Page 86: Ethernet interface, L02cpu/26cpu-bt
86
E SR-750 UM
Configuring the KV Series
RS-232C Interface
*1 To use port2, set the interface to "RS-232C".
*2 For KV BUILDER/KV STUDIO mode, a fixed value is used.
Ethernet Interface
MELSEC Series Configuration
RS-232C Interface
QJ71C24N/-R2
Set communication conditions with the GX-Developer.
("I/O assignment configuration" in "PC parameters")
("Option configuration" under "I/O assignment settings" in "PC parameters")
("Switch configuration" under "I/O assignment configuration" in "PC parameters")
Operation
KV BUILDER/KV STUDIO mode
Interface
RS-232C
*1
Division
0
Baud rate
Automatic
*2
Data bit length
8 bits
*2
Parity
Even (e)
*2
Stop bit length
1 bit
*2
Checksum
None
*2
RS/CSFlow control
Disable
IP address
192.168.0.10 (default)
Subnet mask
255.255.255.0 (default)
Port (VT)
8502 (default)
Type
Intelligent
Type name
Name of the unit to be installed
Points
32 points
First XY
First output signal of the target unit (hexadecimal number)
Unit type
Serial communication/modem interface unit
Unit type name
Name of the unit to be installed
Setting item
Value
Operation configuration
Independent
Data bit length
8 bits
Parity bit
Present
Odd/even parity
Odd (o)
Stop bit length
1 bit
Checksum code
Present
Writing during RUN
Allowed
Configuration change
Allowed
Communication rate
configuration
9600 bps
Communication protocol
configuration
MC protocol (format 5)
Division configuration
0
Ethernet Interface
QJ71E71-100/-B5/-B2
Set communication conditions with the GX-Developer.
("I/O assignment configuration" in "PC parameters")
(Target unit number for "Ethernet/CC IE/MELSECNET" in "Network parameters")
("Operation configuration" for "Ethernet/CC IE/MELSECNET" in "Network
parameters")
*1 Configure so that it matches the network.
*
The port number is 5000.
Q03/04/06/10/13/20/26/50/100UDECPU
Set communication conditions with the GX-Developer.
("Built-in Ethernet port configuration" in "PC parameters")
*1 Configure so that it matches the network.
("Built-in Ethernet port configuration" in "PC parameters")
* The port number of the SR-750 Series must be specified in decimal number while
the Q Series port number with Ethernet module installed is specified in
hexadecimal number.
L02CPU/26CPU-BT
Set communication conditions with the GX-Works2.
("Built-in Ethernet port configuration" in "PC parameters")
*1 Make the configuration appropriate to the network.
("Built-in Ethernet port configuration" in "PC parameters")
* The port number of the SR-750 Series must be set in decimal numbers.
Type
Intelligent
Type name
Name of the unit to be installed
Points
32 points
First XY
First output signal of the target unit (hexadecimal number)
Network type
Ethernet
First I/O No.
Number specified in "I/O assignment configuration" in PC
parameters
Network No.
Any number
Group No.
Any number
Division
Any number
Mode
Online
Communication data code
configuration
Binary code communication
Initial timing configuration Always waiting for OPEN (Communication possible during STOP)
IP address
192.168.0.20
*1
Writing permitted during
RUN
Check
Send frame configuration Ethernet (V2.0)
TCP living confirmation
configuration
KeepAlive is used.
IP address
192.168.0.20 *1
Subnet mask patterns
255.255.255.0
*1
Default router IP address
192.168.0.254
*1
Communication data code
configuration
Binary code communication
Writing permitted during
RUN
(FTP and MC protocol)
Check
Protocol
UDP
Open system
MC protocol
Port number with Ethernet
module installed
232C (hexadecimal number) * Any number
Example)
Hexadecimal number
Decimal number
232C
9004
IP address
192.168.0.20
*1
Subnet mask patterns
255.255.255.0
*1
Default router IP address
192.168.0.254
*1
Communication data code
configuration
Binary code communication
Writing permitted during
RUN
(FTP and MC protocol)
Check
Protocol
UDP
Open system
MC protocol
Port number with Ethernet
module installed
232C (hexadecimal number) * Any number