Configuring the KV Series

RS-232C Interface

*1 To use port2, set the interface to "RS-232C".
*2 For KV BUILDER/KV STUDIO mode, a fixed value is used.

Ethernet Interface

MELSEC Series Configuration

RS-232C Interface

„

QJ71C24N/-R2

Set communication conditions with the GX-Developer.
("I/O assignment configuration" in "PC parameters")

("Option configuration" under "I/O assignment settings" in "PC parameters")

("Switch configuration" under "I/O assignment configuration" in "PC parameters")

Operation

KV BUILDER/KV STUDIO mode

Interface

RS-232C

*1

Division

0

Baud rate

Automatic

*2

Data bit length

8 bits

*2

Parity

Even (e)

*2

Stop bit length

1 bit

*2

Checksum

None

*2

RS/CSFlow control

Disable

IP address

192.168.0.10 (default)

Subnet mask

255.255.255.0 (default)

Port (VT)

8502 (default)

Type

Intelligent

Type name

Name of the unit to be installed

Points

32 points

First XY

First output signal of the target unit (hexadecimal number)

Unit type

Serial communication/modem interface unit

Unit type name

Name of the unit to be installed

Setting item

Value

Operation configuration

Independent

Data bit length

8 bits

Parity bit

Present

Odd/even parity

Odd (o)

Stop bit length

1 bit

Checksum code

Present

Writing during RUN

Allowed

Configuration change

Allowed

Communication rate
configuration

9600 bps

Communication protocol
configuration

MC protocol (format 5)

Division configuration

0

Ethernet Interface

„

QJ71E71-100/-B5/-B2

Set communication conditions with the GX-Developer.
("I/O assignment configuration" in "PC parameters")

(Target unit number for "Ethernet/CC IE/MELSECNET" in "Network parameters")

("Operation configuration" for "Ethernet/CC IE/MELSECNET" in "Network
parameters")

*1 Configure so that it matches the network.
*

The port number is 5000.

„

Q03/04/06/10/13/20/26/50/100UDECPU

Set communication conditions with the GX-Developer.
("Built-in Ethernet port configuration" in "PC parameters")

*1 Configure so that it matches the network.
("Built-in Ethernet port configuration" in "PC parameters")

* The port number of the SR-750 Series must be specified in decimal number while

the Q Series port number with Ethernet module installed is specified in
hexadecimal number.

„

L02CPU/26CPU-BT

Set communication conditions with the GX-Works2.
("Built-in Ethernet port configuration" in "PC parameters")

*1 Make the configuration appropriate to the network.
("Built-in Ethernet port configuration" in "PC parameters")

* The port number of the SR-750 Series must be set in decimal numbers.

Type

Intelligent

Type name

Name of the unit to be installed

Points

32 points

First XY

First output signal of the target unit (hexadecimal number)

Network type

Ethernet

First I/O No.

Number specified in "I/O assignment configuration" in PC
parameters

Network No.

Any number

Group No.

Any number

Division

Any number

Mode

Online

Communication data code
configuration

Binary code communication

Initial timing configuration Always waiting for OPEN (Communication possible during STOP)
IP address

192.168.0.20

*1

Writing permitted during
RUN

Check

Send frame configuration Ethernet (V2.0)
TCP living confirmation
configuration

KeepAlive is used.

IP address

192.168.0.20 *1

Subnet mask patterns

255.255.255.0

*1

Default router IP address

192.168.0.254

*1

Communication data code
configuration

Binary code communication

Writing permitted during
RUN
(FTP and MC protocol)

Check

Protocol

UDP

Open system

MC protocol

Port number with Ethernet
module installed

232C (hexadecimal number) * Any number

Example)

Hexadecimal number

Decimal number

232C

9004

IP address

192.168.0.20

*1

Subnet mask patterns

255.255.255.0

*1

Default router IP address

192.168.0.254

*1

Communication data code
configuration

Binary code communication

Writing permitted during
RUN
(FTP and MC protocol)

Check

Protocol

UDP

Open system

MC protocol

Port number with Ethernet
module installed

232C (hexadecimal number) * Any number