Detailed setting for ITF

„

Detailed setting for NW-7 (Codabar)

„

Detailed setting for JAN/EAN/UPC

EAN/JAN-13..........................Check this to allow reading of EAN/JAN 13 digits.
EAN/JAN-8............................Check this to allow reading of EAN/JAN 8 digits.
UPC-E...................................Check this to allow reading of UPC-E.

UPC-A output........................When reading UPC-A, select whether to output the

data as 12 or 13 digits.

.........Check this to append a "0" to the head of read data.

2-digit supplemental..............Check this to read 2-digit supplemental characters.
5-digit supplemental..............Check this to read 5-digit supplemental characters.

.........Check this to allow reading of the UPC code with

supplemental characters only.

GTIN 14 digits output ...........Add a "0" to the head of the data and output as 14

digits.

Quiet zone scale factor (4-11)....Set the quiet zone scale factor.

„

Detailed setting for CODE128

Modulus 10/Weight 3 ....... When this option is

checked, [Send check-
digit] is enabled.

Send check-digit .............. Check this to send read

data, including the check
digit, to the host
computer.

Quiet zone scale factor (4-11) ... Set the quiet zone scale

factor.

Send start/stop characters... Select the Start/Stop

Characters.

Validate check-digit .......... When this option is

checked, [Check-digit
algorithm] and [Send
check-digit] are enabled.

Check-digit algorithm........ Select the method used

for the check digit
calculation.

Send check-digit............... Check this to send read

data, including the check
digit, to the host
computer.

Quiet zone scale factor (4-11).... Set the quiet zone scale

factor.

Add '0' as system code
UPC-E

Ignore UPC without
supplemental

GS1-128 (UCC/EAN-128) ...Check this to support

GS1-128 (UCC/EAN-128).
The SR-750 Series
outputs "FNC1," which
displays the variable
length separator via [GS]
(0x1D).

Quiet zone scale factor (4-11).... Set the quiet zone scale

factor.

„

Detailed setting for GS1 DataBar

Communication1

This section explains how to set the communication configuration for the SR-750
Series. Same configuration can be set in the Table tab.

(1) : RS-232C communication condition settings

Set these according to the external device to connect.
• Baud Rate

Select 9600, 19200, 38400, 57600, or 115200 bps.
Default: 115200 bps

• Data Bits

Select the data length of either 7 or 8 bits.
Default: 8 bits

• Parity

Select None, Even, or Odd.
Default: Even

• Stop Bit

Select 1 or 2 bits.
Default: 1 bit

• Protocol

Select None, PASS/RTRY, or ACK/NAK for the communication protocol.
Default: None

(2) : Ethernet communication condition settings

Set these according to the network to connect.
• IP address

Set the IP address for the SR-750 Series.
Default: 192.168.100.100

• Subnet Mask

Set the subnet mask for the SR-750 Series.
Default: 255.255.255.0

• Default Gateway

Set the default gateway for the SR-750 Series.
Default: 0.0.0.0

GS1 DataBar Truncated ... Check this to allow

reading of GS1 DataBar
Omnidirectional/GS1
DataBar Truncated.

..... Check this to allow

reading of GS1 DataBar
Stacked/GS1 DataBar
Stacked Omnidirectional.

GS1 DataBar Limited ....... Check this to allow

reading of GS1 DataBar
Limited.

GS1 DataBar Expanded... Check this to allow

reading of GS1 DataBar
Expanded.

..... Check this to allow

reading of GS1 DataBar
Expanded Stacked.

..... Set the GS1 DataBar

Expanded Stacked
(Number of rows).

..... Set the quiet zone scale

factor.

GS1 DataBar Stacked
(Omnidirectional)

GS1 DataBar
Expanded Stacked

GS1 DataBar Expanded
Stacked (Number of rows)
(2-11)
Limited right space
scaling factor (0-11)

(1)

(2)