Table] tab, Communication1, Communication2 – KEYENCE SR-750 Series User Manual
Page 43
43
E SR-750 UM
(2) • Image save mode
Default
: Save final bank image
Setting range : Save final bank image, save specified number of images
from timing ON, save specified number of images before
timing OFF
• Number of images saved
If the number of images to save has been specified from timing ON/OFF, then
specify this number.
Default
: 10
Setting range : 1 to 10
FTP Settings
Set if Send by FTP is selected in saving images, and the SR-750 Series device is
operating as a client.
(3) • IP Address
Set the IP address of the connection destination FTP server.
Default
: 0.0.0.0
Setting range : 0.0.0.0 to 255.255.255.255
• User Account/Password
Set the user account name and password of the destination FTP server.
Default
: User Account: admin
Password: admin
Setting range : Specify up to 16 ASCII or hexadecimal characters
• Passive mode
Default
: Disabled (no check mark)
Setting range : Disable, Enable
• Format
Default
: JPEG
Setting range : Bitmap, JPEG
• Quality (JPEG)
Set this when JPEG is selected as the format setting.
Default
: 5
Setting range : 1 to 10
• Binning
Default
: 1/4 skipping
Setting range : No binning, 1/4 skipping, 1/16 skipping, 1/64 skipping
(4) Edit image file name
When setting the edit image file name function, check "Use script".
* Valid only in FTP transmission
[Table] tab
On the list of this tab, you can set items that can be set in [Communication1],
[Communication2], [Operation], [I/O] and [Saving images] tabs.
Defaults and settings ranges are the same as those in each respective tabs.
Some functions can only be configured on the [Table] tab.
(1) Search box
Search whether the input words are present in the Table.
(1)
Communication1
RS-232C
• Baud rate
Sets the baud rate.
Default
: 115200 bps
Setting range : 9600, 19200, 38400, 57600, or 115200 bps
• Data length
Sets the data bit length.
Default
: 8 bits
Setting range : 7 or 8 bits
• Parity
Sets the parity.
Default
: Even
Setting range : None, Even, or Odd
• Stop bit
Sets the stop bit length.
Default
: 1 bit
Setting range : 1 or 2 bits
• Protocol
Sets the output protocol for RS-232C read data.
Default
: None
Setting range : None, PASS/RTRY, or ACK/NAK
Ethernet
• IP address
Sets the IP address.
Default
: 192.168.100.100
• Subnet Mask
Sets the subnet mask.
Default
: 24 (255.255.255.0)
Setting range : 8 to 30 (255.0.0.0 to 255.255.255.252)
• Default Gateway
Sets the default gateway.
Default
: 0.0.0.0
Communication2
Command port
• Interface
Select the interface to perform command communication.
Default
: RS-232C
Setting range : Not used, RS-232C, Ethernet
• Port (Waiting)
Sets the port number to perform command communication. *Only when the
interface is set to Ethernet
Default
: 9004
Setting range : 1024 to 65535
* 9013, 9014, 9015, 9016, 5900, 5910, and 44818 cannot be
used as they are reserved for the main unit system.
• Keep Alive
Sets the keep-alive function for command communication. *Only when the
interface is set to Ethernet
Default
: Enable
Setting range : Enable or Disable
Data port 1
• Interface
Sets the interface to perform PC host output.
Default
: RS-232C
Setting range : Not used, RS-232C, Ethernet
• Remote IP address
Sets the IP address of the PC host. *Only when the interface is set to Ethernet
Default
: 0.0.0.0 * When 0.0.0.0 is set, the SR-750 performs server
operations only.
Setting range : 0.0.0.0 to 255.255.255.255
• Remote port
Sets the port number of the PC host. *Only when the interface is set to Ethernet
Default
: 9004
Setting range : 1024 to 65535