beautypg.com

Operation] tab, Master/slave, Code quality verification – KEYENCE SR-750 Series User Manual

Page 41

background image

41

E SR-750 UM

[Operation] tab

Configures SR-750 Series operation. These can be set or changed in the [Table]
tab.

(1) Reading Mode

Select one of the following four choices.
Single ........... single label read mode
Multi1............ multi-label read mode 1
Multi2............ multi-label read mode 2
Burst read .... burst reading mode
When Multi1 or Multi2 is selected, the following window is displayed. Set Laser-
Aim Pulse Duration.

(2) Data Transmission

When specifying single label read mode or multi-label read mode 2, select from
the following 2 options.
• Send after read
• Send after timing off

(3) Duplicate Reading Prevention Interval

Set when multi-label read mode 1 is specified.

Default

: 1000 ms

Setting range : 0 to 25500 ms (Specify in units of 100 ms)

Important

When Multi1 is selected, the following window is displayed. Set
Duplicate Reading Prevent Interval Reset.

"3-12 Duplicate reading prevention interval reset (Page 24)"

Burst read settings
Specify burst read mode and the follow screen will be displayed.

Burst Interval

Default

: 0 ms

Setting range : 0 to 255 ms (Specify in units of 1 ms)

• Burst Bank

Default

: Bank1

Setting range : Bank1 to Bank10

• Burst Count

Default

: 3

Setting range : 1 to 8

(4) Timing Mode

Select one of the following two choices.
• Level trigger
• One-shot trigger

If one-shot trigger is selected, then set the one-shot duration.
Default

: 1000 ms

Setting range : 100 to 25500 ms (Specify in units of 10 ms)

(5) Timing On Command, Timing Off Command, Read Error String

Specify up to 8 ASCII or hexadecimal characters.

Timing On Command default : LON (4C4F4E)
Timing Off Command default : LOFF (4C4F4646)
Read Error String default

: ERROR (4552524F52)

(1)

(3)

(2)

(4)

(5)

Master/Slave

(1) : Operation setting

Sets the Master/Slave function operation.
• Default

: Not used

• Setting range : Not used, Multi Drop, Multi Head

(2) : Group name

Determines the group name to use the Master/Slave function.
• Default

: GROUP01

• Setting range : Up to 16 characters

Set with ASCII.

(3) : Unit ID

Sets ID as Master unit or Slave unit.
• Default

: Check "Use as Master"

• Setting range : "Use as Master" or Slave ID "1 to 31"

(4) : Multi Head

Sets the number of read data when using the Multi Head.
• Default

: 1

• Setting range : 1 to 8

(5) : Append Information

Sets to append group names or Master/Slave ID when using the Master/
Slave function.
• Default

: None

(6) : Master/Slave Reader View

Displays the information of the reader that uses the Master/Slave function
among readers that have been registered to AutoID Network Navigator.

Code quality verification

(1) Matching Level Judgment

Sets the Matching Level Judgment function.
Default

: Disable

Changing the setting to "Enable" will enable the setting items for threshold or
appending matching level.

(2) Code quality verification

Sets the Code quality verification function. Check the code quality verification
standard.
With the checked standard, set the threshold for the verified result or additional
data of grade.
Additional data setting for detailed items of verified results can also be made.

(3)

(5)

(6)

(4)

(1)

(2)

(2)

(1)