Silent mode setting procedure

The following 2 procedures for setting silent mode are available:
• Setting using the AutoID Network Navigator
• Setting with a command

Data subject to data communication restraint

By configuring the SR-750 Series, the following data communication can be restrained.

„

Setting items and setting details using the AutoID Network Navigator

3-9

SR-600 Compatible Output Mode

This section describes the SR-600 compatible output mode of the SR-750 Series.

SR-600 compatible output mode

The SR-750 Series supports the Ethernet communication, so the operation command
format and response code format have been changed from the previous SR-600 Series.
When using the SR-750 Series in the SR-600 Series operation process or using
the control program for the SR-600 Series, setting the SR-600 compatible output
mode to Enable results in reduction in man-hours for program change.
• Standard mode

• SR-600 compatible output mode

SR-600 compatible output mode functions

Commands and responses set to Enable in the SR-600 compatible output mode are as follows.

„

Operation commands

Setting item

Data subject to output restraint

Read (Comparison) OK

Read data
Read data judged as Comparison OK as a result of preset verification.

Comparison NG

Preset Comparison NG data
Read data judged as Comparison NG as a result of preset verification.

Read ERROR

Read error data

Stable Reading (OK/NG)

Stable reading data
Read data whose matching level or Code quality verification
result is judged as more than the threshold

Unstable Reading (OK/NG)

Unstable reading data
Read data whose matching level or Code quality verification
result is judged as less than the threshold

Preset Result

Preset registration result data

Test Mode

Measured data in test mode

Command

name

Command

SR-750 Series normal output

SR-600 Compatible output

Response

Error code

Response

Error code

Trigger input ON

LON

OK, LON

ER, LON, ee

(N/A)

(N/A)

Trigger input ON
(Bank settings)

LONbb

LON, bb

Trigger input OFF

LOFF

OK, LOFF

ER, LOFF, ee

(N/A)

(N/A)

Start preset data
registration

PRON

OK, PRON

ER, PRON,

ee

(N/A)

(N/A)

End preset data
registration

PROFF

OK, PROFF

ER, PROFF,

ee

(N/A)

(N/A)

Start reading the
quick setup code

RCON

OK, RCON

ER, RCON,

ee

OK

ERRee

End reading the
quick setup code

RCOFF

OK, RCOFF

ER, RCOFF,

ee

OK

ERRee

Check the quick
setup code
reading status

RCCHK

OK, RCCHK,

Obtained

value

ER, RCCHK,

ee

Obtained

value

ERRee

Check the input
terminal status

INCHK, m

OK, INCHK,

Obtained

value

ER, INCHK,

ee

Obtained

value

ERRee

INmCHK

OK, INmCHK,

Obtained

value

ER, INmCHK,

ee

Output terminal
ON control
(individual
control)

OUTON, m

OK, OUTON

ER, OUTON,

ee

Obtained

value

ERRee

OUTmON

OK, OUTmON

ER,

OUTmON, ee

SR-750

PC or PLC

(1) LON

(2) OK, LON

(3) Read data

SR-750

PC or PLC

(1) LON

(2) Read data

„

Test mode commands

* bb

: Parameter bank No.

ee

: Error code

m

: Pin No.

Obtained value : Value obtained after command operation

How to set the SR-600 Series compatible output mode

Change the setting according to the following methods to set the SR-600 Series
compatible output mode to Enable.
• Change the setting using AutoID Network Navigator.

On the AutoID Network Navigator, select [Table] tab - [Others] - [Trigger command
response] - [Specify response character], and then specify SR-600 compatible. (Page 48)

• Send the setting command to set

Output terminal
OFF control
(individual
control)

OUTOFF, m OK, OUTOFF

ER, OUTOFF,

ee

Obtained

value

ERRee

OUTmOFF

OK,

OUTmOFF

ER,

OUTmOFF,

ee

Output terminal
ON control
(batch control)

ALLON

OK, ALLON

ER, ALLON,

ee

OK

ERRee

Output terminal
OFF control
(batch control)

ALLOFF

OK, ALLOFF

ER, ALLOFF,

ee

OK

ERRee

Soft reset

RESET

OK, RESET

(N/A)

OK

(N/A)

Clearing the
send buffer

BCLR

OK, BCLR

(N/A)

OK

(N/A)

Check reading
history

NUM

OK, NUM,

Obtained

value

ER, NUM, ee

Obtained

value

ERRee

Capture

SHOTbb

OK, SHOT,

File name

ER, SHOT, ee

OK

ERRee

SHOT, bb

Start tuning

TUNE, bb

OK, TUNE

ER, TUNE, ee

OK

ERRee

TUNEbb

Cancel tuning

TQUIT

OK, TQUIT

ER, TQUIT,

ee

OK

ERRee

Obtain the
alternate order

BANKORDER

OK,

BANKORDER,
Obtained value

ER,

BANKORDER,

ee

Obtained

value

ERRee

Initialize the
parameter bank

BANKCLR,

bb

OK,

BANKCLR

ER,

BANKCLR, ee

OK

ERRee

BANKCLRb

b

Save setting

SAVE

OK, SAVE

ER, SAVE, ee

OK

ERRee

Initialize the
settings

DFLT

OK, DFLT

ER, DFLT, ee

OK

ERRee

Obtain the
command status

CMDSTAT

OK,

CMDSTAT,

Obtained

value

(N/A)

Obtained

value

(N/A)

Obtain the error
status

ERRSTAT

OK,

ERRSTAT,

Obtained

value

(N/A)

Obtained

value

(N/A)

Erase error
images

ICLR, bb

OK, ICLR

ER, ICLR, ee

OK

ERRee

ICLRbb

Command

name

Command

SR-750 Series normal output

SR-600 Compatible output

Response

Error code

Response

Error code

Start reading
rate test mode
(offline)

TEST1

OK, TEST1

ER, TEST1,

ee

OK

ERRee

TEST1, bb

TEST1bb

Start reading
rate test mode
(online)

#TEST1

OK, #TEST1

ER, #TEST1,

ee

OK

ERRee

#TEST1, bb

#TEST1bb

Start processing
time test mode
(offline)

TEST2

OK, TEST2

ER, TEST2,

ee

OK

ERRee

TEST2, bb

TEST2bb

Start processing
time test mode
(online)

#TEST2

OK, #TEST2

ER, #TEST2,

ee

OK

ERRee

#TEST2, bb

#TEST2bb

Start position
test mode
(offline)

#TEST3

OK, TEST3

ER, TEST3,

ee

OK

ERRee

#TEST3, bb

#TEST3bb

End test mode
(offline)

QUIT

OK, QUIT

ER, QUIT, ee

OK

ERRee

End test mode
(online)

#QUIT

OK, #QUIT

ER, #QUIT, ee

OK

ERRee

Command

name

Command

SR-750 Series normal output

SR-600 Compatible output

Response

Error code

Response

Error code