9 sr-600 compatible output mode, Sr-600 compatible output mode, Silent mode setting procedure – KEYENCE SR-750 Series User Manual
Page 19: Data subject to data communication restraint, Sr-600 compatible output mode functions, Operation commands, Test mode commands
19
E SR-750 UM
Silent mode setting procedure
The following 2 procedures for setting silent mode are available:
• Setting using the AutoID Network Navigator
• Setting with a command
Data subject to data communication restraint
By configuring the SR-750 Series, the following data communication can be restrained.
Setting items and setting details using the AutoID Network Navigator
3-9
SR-600 Compatible Output Mode
This section describes the SR-600 compatible output mode of the SR-750 Series.
SR-600 compatible output mode
The SR-750 Series supports the Ethernet communication, so the operation command
format and response code format have been changed from the previous SR-600 Series.
When using the SR-750 Series in the SR-600 Series operation process or using
the control program for the SR-600 Series, setting the SR-600 compatible output
mode to Enable results in reduction in man-hours for program change.
• Standard mode
• SR-600 compatible output mode
SR-600 compatible output mode functions
Commands and responses set to Enable in the SR-600 compatible output mode are as follows.
Operation commands
Setting item
Data subject to output restraint
Read (Comparison) OK
Read data
Read data judged as Comparison OK as a result of preset verification.
Comparison NG
Preset Comparison NG data
Read data judged as Comparison NG as a result of preset verification.
Read ERROR
Read error data
Stable Reading (OK/NG)
Stable reading data
Read data whose matching level or Code quality verification
result is judged as more than the threshold
Unstable Reading (OK/NG)
Unstable reading data
Read data whose matching level or Code quality verification
result is judged as less than the threshold
Preset Result
Preset registration result data
Test Mode
Measured data in test mode
Command
name
Command
SR-750 Series normal output
SR-600 Compatible output
Response
Error code
Response
Error code
Trigger input ON
LON
OK, LON
ER, LON, ee
(N/A)
(N/A)
Trigger input ON
(Bank settings)
LONbb
LON, bb
Trigger input OFF
LOFF
OK, LOFF
ER, LOFF, ee
(N/A)
(N/A)
Start preset data
registration
PRON
OK, PRON
ER, PRON,
ee
(N/A)
(N/A)
End preset data
registration
PROFF
OK, PROFF
ER, PROFF,
ee
(N/A)
(N/A)
Start reading the
quick setup code
RCON
OK, RCON
ER, RCON,
ee
OK
ERRee
End reading the
quick setup code
RCOFF
OK, RCOFF
ER, RCOFF,
ee
OK
ERRee
Check the quick
setup code
reading status
RCCHK
OK, RCCHK,
Obtained
value
ER, RCCHK,
ee
Obtained
value
ERRee
Check the input
terminal status
INCHK, m
OK, INCHK,
Obtained
value
ER, INCHK,
ee
Obtained
value
ERRee
INmCHK
OK, INmCHK,
Obtained
value
ER, INmCHK,
ee
Output terminal
ON control
(individual
control)
OUTON, m
OK, OUTON
ER, OUTON,
ee
Obtained
value
ERRee
OUTmON
OK, OUTmON
ER,
OUTmON, ee
SR-750
PC or PLC
(1) LON
(2) OK, LON
(3) Read data
SR-750
PC or PLC
(1) LON
(2) Read data
Test mode commands
* bb
: Parameter bank No.
ee
: Error code
m
: Pin No.
Obtained value : Value obtained after command operation
How to set the SR-600 Series compatible output mode
Change the setting according to the following methods to set the SR-600 Series
compatible output mode to Enable.
• Change the setting using AutoID Network Navigator.
On the AutoID Network Navigator, select [Table] tab - [Others] - [Trigger command
response] - [Specify response character], and then specify SR-600 compatible. (Page 48)
• Send the setting command to set
Output terminal
OFF control
(individual
control)
OUTOFF, m OK, OUTOFF
ER, OUTOFF,
ee
Obtained
value
ERRee
OUTmOFF
OK,
OUTmOFF
ER,
OUTmOFF,
ee
Output terminal
ON control
(batch control)
ALLON
OK, ALLON
ER, ALLON,
ee
OK
ERRee
Output terminal
OFF control
(batch control)
ALLOFF
OK, ALLOFF
ER, ALLOFF,
ee
OK
ERRee
Soft reset
RESET
OK, RESET
(N/A)
OK
(N/A)
Clearing the
send buffer
BCLR
OK, BCLR
(N/A)
OK
(N/A)
Check reading
history
NUM
OK, NUM,
Obtained
value
ER, NUM, ee
Obtained
value
ERRee
Capture
SHOTbb
OK, SHOT,
File name
ER, SHOT, ee
OK
ERRee
SHOT, bb
Start tuning
TUNE, bb
OK, TUNE
ER, TUNE, ee
OK
ERRee
TUNEbb
Cancel tuning
TQUIT
OK, TQUIT
ER, TQUIT,
ee
OK
ERRee
Obtain the
alternate order
BANKORDER
OK,
BANKORDER,
Obtained value
ER,
BANKORDER,
ee
Obtained
value
ERRee
Initialize the
parameter bank
BANKCLR,
bb
OK,
BANKCLR
ER,
BANKCLR, ee
OK
ERRee
BANKCLRb
b
Save setting
SAVE
OK, SAVE
ER, SAVE, ee
OK
ERRee
Initialize the
settings
DFLT
OK, DFLT
ER, DFLT, ee
OK
ERRee
Obtain the
command status
CMDSTAT
OK,
CMDSTAT,
Obtained
value
(N/A)
Obtained
value
(N/A)
Obtain the error
status
ERRSTAT
OK,
ERRSTAT,
Obtained
value
(N/A)
Obtained
value
(N/A)
Erase error
images
ICLR, bb
OK, ICLR
ER, ICLR, ee
OK
ERRee
ICLRbb
Command
name
Command
SR-750 Series normal output
SR-600 Compatible output
Response
Error code
Response
Error code
Start reading
rate test mode
(offline)
TEST1
OK, TEST1
ER, TEST1,
ee
OK
ERRee
TEST1, bb
TEST1bb
Start reading
rate test mode
(online)
#TEST1
OK, #TEST1
ER, #TEST1,
ee
OK
ERRee
#TEST1, bb
#TEST1bb
Start processing
time test mode
(offline)
TEST2
OK, TEST2
ER, TEST2,
ee
OK
ERRee
TEST2, bb
TEST2bb
Start processing
time test mode
(online)
#TEST2
OK, #TEST2
ER, #TEST2,
ee
OK
ERRee
#TEST2, bb
#TEST2bb
Start position
test mode
(offline)
#TEST3
OK, TEST3
ER, TEST3,
ee
OK
ERRee
#TEST3, bb
#TEST3bb
End test mode
(offline)
QUIT
OK, QUIT
ER, QUIT, ee
OK
ERRee
End test mode
(online)
#QUIT
OK, #QUIT
ER, #QUIT, ee
OK
ERRee
Command
name
Command
SR-750 Series normal output
SR-600 Compatible output
Response
Error code
Response