Operation configuration command format (wp/rp), I/o terminal setting – KEYENCE SR-750 Series User Manual
Page 78
78
E SR-750 UM
NW-7 (Codabar)
settings
0900
03 to 50 Maximum read length
50
0901
03 to 50 Minimum read length
4
0902
4 to 11
Quiet zone scale factor
7
0903
0,1
Send start/stop characters
0 : Disable
1 : Enable
1
0904
0,1
Send start/stop characters letter
type
0 : as lowercase
1 : as UPPERCASE
0
0905
0,1
Inspect check-digit
0 : Disable
1 : Enable
0
0906
0,1
Send check-digit
0 : Disable
1 : Enable
1
0907
0 to 6
Check-digit type
0 : Modulus 16
1 : Modulus 11
2 : Modulus 10/Weight 2
3 : Modulus 10/Weight 3
4 : Check DR
5 : Modulus 11-A
6 : Luhn
0
JAN/EAN/UPC settings
1002
4 to 11
Quiet zone scale factor
7
1003
0,1
UPC-E reading
0 : Disable
1 : Enable
1
1004
0,1
EAN/JAN 8 digits reading
0 : Disable
1 : Enable
1
1005
0,1
EAN/JAN 13 digits reading
0 : Disable
1 : Enable
1
1006
0,1
UPC-A Output
0 : Output in 13 digits
1 : Output in 12 digits
0
1007
0,1
Add "number system" to UPC-E
0 : Disable
1 : Enable
0
1008
0,1
2-digit supplemental
0 : Disable
1 : Enable
1
1009
0,1
5-digit supplemental
0 : Disable
1 : Enable
1
1010
0,1
Ignore UPC without supplemental
0 : Disable
1 : Enable
0
1011
0,1
GTIN compatible 14-digit output
0 : Disable
1 : Enable
0
CODE128
1100
001 to 128 Maximum read length
128
1101
001 to 128 Minimum read length
1
1102
4 to 11
Quiet zone scale factor
7
1103
0,1
GS1-128
0 : Disable
1 : Enable
1
Function
Command
Number
Setting
value
Explanation
Default
Operation Configuration Command Format (WP/RP)
Operation configuration command is sent in the following format:
• Configuration change
Send command
Response
Normal process
Abnormal process
• Configuration confirmation
Send command
Response
Normal process
Abnormal process
mmm : Command number Fixed to 3 bytes
nnn… : Setting value (varies according to command number)
example) When setting the trigger input measurement method to "One-shot
trigger" (one-shot signal trigger)
Configuration change
Send command
WP, 101, 1
Response (Normal process) OK, WP
Configuration confirmation Send command
RP, 101
Response (Normal process) OK, RP, 1
I/O terminal setting
Function
Command
Number
Setting
value
Explanation
Default
IN
terminal
setting
IN1 terminal
function
000
0 to 8
0 : Not use
1 : Trigger input
2 : Preset Input
3 : Start test mode.
5 : Clear PLC link error
8 : Tuning operation
1
IN2 terminal
function
001
0 to 8
0 : Not use
1 : Trigger input
2 : Preset Input
3 : Start test mode.
5 : Clear PLC link error
8 : Tuning operation
2
IN1 terminal
test mode
assignment
002
1 to 3
1 : Reading rate test
2 : Processing time test
3 : Position test
1
IN2 terminal
test mode
assignment
003
1 to 3
1 : Reading rate test
2 : Processing time test
3 : Position test
1
IN1 terminal
input at
power-on
006
0, 1
0 : Not use
1 : Enable
0
IN2 terminal
input at
power-on
007
0, 1
0 : Not use
1 : Enable
0
Synchronizat
ion of IN1
and TIMING
LED
008
0, 1
0 : Disable
1 : Enable
1
Synchronizat
ion of IN2
and TIMING
LED
009
0, 1
0 : Disable
1 : Enable
0
Input polarity
010
0, 1
0 : Normal open point
1 : Normal close point
0
Input pulse
width
011
0 to 2
0 : 1 ms
1 : 2 ms
2 : 10 ms
0
WP
,
mmm
,
nnn…
OK
,
WP
ER
,
WP
,
ee
ee: Error code
RP
,
mmm
OK
,
RP
,
nnn…
ER
,
RP
,
ee
ee: Error code