Operation mode settings – KEYENCE SR-750 Series User Manual
Page 79
79
E SR-750 UM
Operation mode settings
OUT
terminal
setting
OUT1
terminal
assignment
020
0 to
3103
0 : Not selected
1 : OK
2 : NG
4 : ERROR
8 : STABLE
16 : PRESET OK
32 : TRG BUSY
64 : LOCK BUSY
128 : MODE BUSY
256 : ERROR BUSY
1024 : UNSTABLE
2048 : TUNING OK
1
OUT2
terminal
assignment
021
0 to
3103
0 : Not selected
1 : OK
2 : NG
4 : ERROR
8 : STABLE
16 : PRESET OK
32 : TRG BUSY
64 : LOCK BUSY
128 : MODE BUSY
256 : ERROR BUSY
1024 : UNSTABLE
2048 : TUNING OK
6
OUT3
terminal
assignment
022
0 to
3103
0 : Not selected
1 : OK
2 : NG
4 : ERROR
8 : STABLE
16 : PRESET OK
32 : TRG BUSY
64 : LOCK BUSY
128 : MODE BUSY
256 : ERROR BUSY
512 : EXT. LIGHT
1024 : UNSTABLE
2048 : TUNING OK
480
TRG_BUSY
output upon
power-up
024
0, 1
0 : Disable
1 : Enable
1
Output ON
duration for
OUT terminal
025
001 to
255
Specify in units of 10 ms
50
External
lighting
output
polarity
026
0, 1
0 : N.O. (Normally open)
1 : N.C. (Normally closed)
0
Function
Command
Number
Setting
value
Explanation
Default
Trigger input
measurement
method
Trigger input
measurement
method
101
0, 1
0 : Level trigger
1 : One-shot trigger
0
One-shot
trigger
duration
102
0003 to
2550
Specify in units of 10 ms
100
Trigger input
ON
command
character
string
103
hhhhhhh
h···
Specify up to 8 characters (16 HEX
bytes) from HEX (0x00 to 0x7F).
4C4F4E
(LON)
Trigger input
OFF
command
character
string
104
hhhhhhh
h···
Specify up to 8 characters (16 HEX
bytes) from HEX (0x00 to 0x7F).
4C4F4646
(LOFF)
Trigger input
ON/OFF
recognition
with one
character
105
0, 1
0 : Not use
1 : Enable
* When set to Enable, only the
following control codes can be
specified to the trigger input ON/
OFF commands:
SOH (0x01) SO (0x0e)
EM (0x19)
STX (0x02) SI (0x0f)
SUB (0x1a)
ETX (0x03) DLE (0x10) FS (0x1c)
EOT (0x04) DC1 (0x11) GS (0x1d)
ENQ (0x05) DC2 (0x12) RS (0x1e)
BEL (0x07) DC3 (0x13) US (0x1f)
BS (0x08)
DC4 (0x14)
HT (0x09)
SYN (0x16)
VT (0x0b)
ETB (0x17)
FF (0x0c)
CAN (0x18)
* If STX (0x02) or ETX (0x03) is
set for either the timing ON or
OFF command, the command is
not recognized in the "
command
0
Function
Command
Number
Setting
value
Explanation
Default
Specify the setting
by sum of the
values of the items.
Specify the setting
by sum of the
values of the items.
Specify the setting
by sum of the
values of the items.
Reading
behavior
setting
Reading
mode setting
200
0 to 3
0 : Single
1 : Multi1
2 : Multi2
3 : Burst
0
Data
transmission
201
0, 1
0 : Send after read
1 : Send after timing off
0
Multi read
duplicate
reading
prevention
interval
202
000 to
255
Specify by the 100 ms
10
Duplicate
reading
prevention
interval reset
213
0, 1
0 : Reset when a different code
is read
1 : Do not reset during duplicate
prevention interval.
Alternate
start bank
203
01 to 10
1
Specifying
alternate
order
204
0, 1
0 : Order of parameter bank
number
1 : Begin with successful bank
1
Read error
character
string
205
hhhhhhh
h…
Specify a maximum of 8
characters (HEX 16 bytes) with
HEX (0x00 to 0x7F).
Set FF if error codes are not
output.
4552524F52
(ERROR)
Matching
level OK/NG
judgment
206
0, 1
0 : Enable
1 : Disable
0
Matching
level
threshold
207
00 to 99
Laser-aim
pulse
duration in
Multi read
209
00 to 99 Specify by the 10 ms
10
Parameter
bank LED
display when
reading
212
0, 1
0 : Disable
1 : Enable
1
Burst interval
208
000 to
255
Specify by the 1 ms
0
Burst count
210
1 to 8
3
Burst bank
211
01 to 10
1
Code
quality
verification
function
Code quality
verification
standard
selection
230
0 to F
0 : No selected
1 : ISO/IEC 15415
2 : ISO/IEC TR 29158
(AIM DPM-1-2006)
4 : SAE AS9132
8 : SEMI T10-0701
Specify the setting with HEX using
sum of each item.
0
ISO/
IEC15415
verification
threshold
231
0 to 4
0 : Disable
1 : D
2 : C
3 : B
4 : A
0
ISO/IEC TR
29158 (AIM
DPM-1-
2006)
verification
threshold
232
0 to 4
0 : Disable
1 : D
2 : C
3 : B
4 : A
0
SAE AS9132
verification
threshold
233
0,1
0 : Disable
1 : Enable
0
Grade
expression
setting when
appending
values to
verification
result
350
0,1
0 : Alphabet
1 : Numerical value
0
Detailed item
addition
setting when
appending
values to
verification
result
351
0,1
0 : Do not append
1 : Append
0
Evaluation
value
addition
setting when
appending
values to
verification
result
352
0,1
0 : Do not append
1 : Append
0
Function
Command
Number
Setting
value
Explanation
Default