beautypg.com

Operation mode settings – KEYENCE SR-750 Series User Manual

Page 79

background image

79

E SR-750 UM

„

Operation mode settings

OUT
terminal
setting

OUT1
terminal
assignment

020

0 to
3103

0 : Not selected
1 : OK
2 : NG
4 : ERROR
8 : STABLE

16 : PRESET OK
32 : TRG BUSY
64 : LOCK BUSY

128 : MODE BUSY
256 : ERROR BUSY

1024 : UNSTABLE
2048 : TUNING OK

1

OUT2
terminal
assignment

021

0 to
3103

0 : Not selected
1 : OK
2 : NG
4 : ERROR
8 : STABLE

16 : PRESET OK
32 : TRG BUSY
64 : LOCK BUSY

128 : MODE BUSY
256 : ERROR BUSY

1024 : UNSTABLE
2048 : TUNING OK

6

OUT3
terminal
assignment

022

0 to
3103

0 : Not selected
1 : OK
2 : NG
4 : ERROR
8 : STABLE

16 : PRESET OK
32 : TRG BUSY
64 : LOCK BUSY

128 : MODE BUSY
256 : ERROR BUSY
512 : EXT. LIGHT

1024 : UNSTABLE
2048 : TUNING OK

480

TRG_BUSY
output upon
power-up

024

0, 1

0 : Disable
1 : Enable

1

Output ON
duration for
OUT terminal

025

001 to
255

Specify in units of 10 ms

50

External
lighting
output
polarity

026

0, 1

0 : N.O. (Normally open)
1 : N.C. (Normally closed)

0

Function

Command

Number

Setting

value

Explanation

Default

Trigger input
measurement
method

Trigger input
measurement
method

101

0, 1

0 : Level trigger
1 : One-shot trigger

0

One-shot
trigger
duration

102

0003 to
2550

Specify in units of 10 ms

100

Trigger input
ON
command
character
string

103

hhhhhhh
h···

Specify up to 8 characters (16 HEX
bytes) from HEX (0x00 to 0x7F).

4C4F4E

(LON)

Trigger input
OFF
command
character
string

104

hhhhhhh
h···

Specify up to 8 characters (16 HEX
bytes) from HEX (0x00 to 0x7F).

4C4F4646

(LOFF)

Trigger input
ON/OFF
recognition
with one
character

105

0, 1

0 : Not use
1 : Enable

* When set to Enable, only the

following control codes can be
specified to the trigger input ON/
OFF commands:

SOH (0x01) SO (0x0e)

EM (0x19)

STX (0x02) SI (0x0f)

SUB (0x1a)

ETX (0x03) DLE (0x10) FS (0x1c)
EOT (0x04) DC1 (0x11) GS (0x1d)
ENQ (0x05) DC2 (0x12) RS (0x1e)
BEL (0x07) DC3 (0x13) US (0x1f)
BS (0x08)

DC4 (0x14)

HT (0x09)

SYN (0x16)

VT (0x0b)

ETB (0x17)

FF (0x0c)

CAN (0x18)

* If STX (0x02) or ETX (0x03) is

set for either the timing ON or
OFF command, the command is
not recognized in the "
command " format.

0

Function

Command

Number

Setting

value

Explanation

Default

Specify the setting

by sum of the

values of the items.

Specify the setting

by sum of the

values of the items.

Specify the setting

by sum of the

values of the items.

Reading
behavior
setting

Reading
mode setting

200

0 to 3

0 : Single
1 : Multi1
2 : Multi2
3 : Burst

0

Data
transmission

201

0, 1

0 : Send after read
1 : Send after timing off

0

Multi read
duplicate
reading
prevention
interval

202

000 to
255

Specify by the 100 ms

10

Duplicate
reading
prevention
interval reset

213

0, 1

0 : Reset when a different code

is read

1 : Do not reset during duplicate

prevention interval.

Alternate
start bank

203

01 to 10

1

Specifying
alternate
order

204

0, 1

0 : Order of parameter bank

number

1 : Begin with successful bank

1

Read error
character
string

205

hhhhhhh
h…

Specify a maximum of 8
characters (HEX 16 bytes) with
HEX (0x00 to 0x7F).
Set FF if error codes are not
output.

4552524F52

(ERROR)

Matching
level OK/NG
judgment

206

0, 1

0 : Enable
1 : Disable

0

Matching
level
threshold

207

00 to 99

Laser-aim
pulse
duration in
Multi read

209

00 to 99 Specify by the 10 ms

10

Parameter
bank LED
display when
reading

212

0, 1

0 : Disable
1 : Enable

1

Burst interval

208

000 to
255

Specify by the 1 ms

0

Burst count

210

1 to 8

3

Burst bank

211

01 to 10

1

Code
quality
verification
function

Code quality
verification
standard
selection

230

0 to F

0 : No selected
1 : ISO/IEC 15415
2 : ISO/IEC TR 29158

(AIM DPM-1-2006)

4 : SAE AS9132
8 : SEMI T10-0701

Specify the setting with HEX using
sum of each item.

0

ISO/
IEC15415
verification
threshold

231

0 to 4

0 : Disable
1 : D
2 : C
3 : B
4 : A

0

ISO/IEC TR
29158 (AIM
DPM-1-
2006)
verification
threshold

232

0 to 4

0 : Disable
1 : D
2 : C
3 : B
4 : A

0

SAE AS9132
verification
threshold

233

0,1

0 : Disable
1 : Enable

0

Grade
expression
setting when
appending
values to
verification
result

350

0,1

0 : Alphabet
1 : Numerical value

0

Detailed item
addition
setting when
appending
values to
verification
result

351

0,1

0 : Do not append
1 : Append

0

Evaluation
value
addition
setting when
appending
values to
verification
result

352

0,1

0 : Do not append
1 : Append

0

Function

Command

Number

Setting

value

Explanation

Default