beautypg.com

Scan condition setting „ code setting – KEYENCE SR-750 Series User Manual

Page 76

background image

76

E SR-750 UM

„

Scan condition setting

„

Code setting

Function

Command

Number

Setting

value

Explanation

Default

Lighting

Internal
lighting use

000

0, 1

0 : Not used
1 : Used

1

External
lighting use

004

0, 1

0 : Not used
1 : Used

0

Scanning

Exposure

100

0003 to
0333

Exposure time = setting value ×
30

μs

0003

Dynamic
range

101

2500 to
37500

Specify in units of 2500

10000

Offset

102

000 to 255

Use the default value of 255 for
normal use.

255

Dynamic
range

103

0 to 2

0 : Hi-Sensitive
1 : Hi-SNR
2 : Hi-DR

0

Analog gain

104

10000 to
40000

Specify in units of 625 for the
range from 10000 to 20000
Specify in units of 1250 for the
range from 20000 to 40000

10000

Filter
setting

1st
filter type

200

0 to 7

0 : Disable
1 : Equalize
2 : Expand
3 : Shrink
4 : Open
5 : Close
6 : Median
7 : Unsharp Mask

0

2nd
filter type

201

3rd
filter type

202

4th
filter type

203

1st
filter count

210

1 to 7

Specify with count

1

2nd
filter count

211

3rd
filter count

212

4th
filter count

213

Function

Command

Number

Setting

value

Explanation

Default

Code type

300

1, 2, 5, 6,
7, 9, 10, 11

1 : QR
2 : DataMatrix
5 : GS1 DataBar
6 : CODE39
7 : ITF
9 : NW-7 (Codebar)

10 : JAN/EAN/UPC

11 : CODE128

1

Codes to read

301

01 to 16

1

Allow reduced detection
count

302

0, 1

0 : Do not allow
1 : Allow

0

Maximum read length

303

1 to 7089

7089

Minimum read length

304

1 to 7089

1

Output length limitation

306

0, 1

0 : Disable
1 : Enable

0

Direction of output

307

0, 1

0 : Forward
1 : Backward

0

Length of output

308

1 to 7089

7089

Starting index of output

309

1 to 7089

1

Setting
QR code
reading
version

Specifying
QR Model 1
Code Version

400

0000 to
3FFF

Specifies version 1 to 14 with bit
assign and set with HEX.

3FFF

Specifying
QR Model 2
Code version
(1 to 20)

401

00000 to
FFFFF

Specifies version 1 to 20 with bit
assign and set with HEX.

FFFFF

Specifying
QR Model 2
Code version
(21 to 40)

402

00000 to
FFFFF

Specifies version 21 to 40 with bit
assign and set with HEX.

FFFFF

Specifying
MicroQR
Code Version
(M1 to M4)

403

0 to F

Specifies version M1 to M4 with bit
assign and set with HEX.

F

Specifying the reading
target size of
DataMatrix code

410

0000000 to
3FFFFFFF

Specifies the code size of
DataMatrix code with bit assign
and set with HEX.
„

Square

1st bit: 10x10

13th bit: 44x44

2nd bit: 12x12

14th bit: 48x48

3rd bit: 14x14

15th bit: 52x52

4th bit: 16x16

16th bit: 64x64

5th bit: 18x18

17th bit: 72x72

6th bit: 20x20

18th bit: 80x80

7th bit: 22x22

19th bit: 88x88

8th bit: 24x24

20th bit: 96x96

9th bit: 26x26

21st bit: 104x104

10th bit: 32x32

22nd bit: 120x120

11th bit: 36x36

23rd bit: 132x132

12th bit: 40x40

24th bit: 144x144

„

Rectangle

25th bit: 8x18
26th bit: 8x32
27th bit: 12x26
28th bit: 12x36
29th bit: 16x36
30th bit: 16x48

3FFFFFFF

GS1 DataBar settings

390

0,1

GS1 DataBar Omnidirectional/
Truncated

0 : Disable
1 : Enable

1

391

0,1

GS1 DataBar Stacked/
StackedOmnidirectional

0 : Disable
1 : Enable

1

392

0,1

GS1 DataBar Limited

0 : Disable
1 : Enable

1

393

0,1

GS1 DataBar Expanded

0 : Disable
1 : Enable

1

394

0,1

GS1 DataBar ExpandedStacked

0 : Disable
1 : Enable

1

395

2 to 11

GS1 DataBar Expanded Stacked
(Number of rows) minimum

2

396

2 to 11

GS1 DataBar Expanded Stacked
(Number of rows) maximum

11

CODE39 settings

375

0,1

Send start/stop characters

0 : Disable
1 : Enable

0

376

0,1

Inspect check-digit

0 : Disable
1 : Enable

0

377

0,1

Send check-digit

0 : Disable
1 : Enable

1

379

0,1

Full ASCII conversion

0 : Disable
1 : Enable

0

ITF settings

385

0,1

Inspect check-digit

0 : Disable
1 : Enable

0

386

0,1

Send check-digit

0 : Disable
1 : Enable

1

NW-7 (Codabar)
settings

380

0,1

Send start/stop characters

0 : Disable
1 : Enable

1

381

0,1

Send start/stop characters letter
type

0 : as lowercase
1 : as UPPERCASE

0

382

0,1

Inspect check-digit

0 : Disable
1 : Enable

0

383

0,1

Send check-digit

0 : Disable
1 : Enable

1

384

0 to 6

Check-digit type

0 : Modulus 16
1 : Modulus 11
2 : Modulus 10/Weight 2
3 : Modulus 10/Weight 3
4 : Check DR
5 : Modulus 11-A
6 : Luhn

0

Function

Command

Number

Setting

value

Explanation

Default