3 sr-750 series field of view size, Sr-750 series field of view size, Test tune sr-625 pow err net in stb ok/ng – KEYENCE SR-750 Series User Manual
Page 118
118
E SR-750 UM
Ethernet cable (OP-87356/87357/87358)
NFPA79 compliant Ethernet cable (OP-87359/87360/87361)
* For the dimensions after main unit changes, see the
"SR-750 Series
Additional Functions Manual."
Ethernet assembly plug (OP-87362)
Model
L
OP-87356
2 m
OP-87357
5 m
OP-87358
10 m
44.7
L
47.3
φ
6.4
φ
15
M12
Unit: mm
Model
L
OP-87359
2 m
OP-87360
5 m
OP-87361
10 m
(43.2)
L
(46.5)
(13.5)
(27.4)
φ
6.4
M12
φ
15
Unit: mm
(46.5)
M12
φ
15
Unit: mm
15-3
SR-750 Series Field of View Size
The size of the field of view for the SR-750 Series is as follows.
SR-750HA
SR-750
SR-751
SR-752
SR-752+SR-75L4
SR-752+SR-75L6
* Field of view size other than the above can be confirmed using the introduction
guide for AutoID Network Navigator.
In the introduction guide, reading distance and field of view size have been
calculated by entering the setting distance.
Refer to
"5-12 Installation Guide (Page 53)"
Unit: mm
Reading distance
20
25
30
40
50
60
Field of
view size
Width
15.3
18.6
21.9
28.5
34.5
41.2
Height
10.1
12.3
14.5
18.9
22.9
27.3
Unit: mm
Reading distance
40
50
60
80
100
120
Field of
view size
Width
29.5
35.7
42.6
55.7
69.4
82.4
Height
19.6
23.7
28.2
36.9
46.0
54.6
Unit: mm
Reading distance
50
75
100
130
170
210
Field of
view size
Width
36.4
53.3
70.9
91.1
117.7
145.1
Height
24.2
35.3
46.9
60.4
78.1
96.2
Unit: mm
Reading distance
175
200
225
250
275
300
Field of
view size
Width
45.8
52.1
57.3
64.9
71.5
77.8
Height
30.3
34.5
37.9
42.9
47.3
51.5
Unit: mm
Reading distance
250
300
350
400
450
500
Field of
view size
Width
66
79
92
108
118
131
Height
44
52
61
69
78
87
Unit: mm
Reading distance
500
550
600
650
700
750
Field of
view size
Width
132
145
165
172
185
198
Height
87
96
106
113
122
131
NOTICE
There are cases where, depending on the conditions of the code
or installation environment, a code is unreadable even though
the code to be read fits within the reading range. In the actual
operation, perform sufficient reading tests and confirm stable
reading is achieved.
TEST
TUNE
SR-625
POW
ERR
NET
IN
STB
OK/NG/
Width
Height
Reading distance
Reading area