E SR-750 UM
7-4
Ethernet Communication
Using the Ethernet communication, you can send data from the SR-750 Series, or
send operating instructions or change settings from the control device. This section
describes the basic specifications and functions of the SR-750 Series.
Basic Specifications
Ethernet port specifications
The SR-750 Series supports PoE (Power over Ethernet).
The pin arrangement of the Ethernet port on the SR-750 side is as follows:
• Pin arrangement of KEYENCE Ethernet cable
* When making a cable using the optional connector OP-87362, use a cable of
CAT5e or more.
Ethernet communication settings
SR-750 Series settings
Use the AutoID Network Navigator to set the following settings:
• IP address
• Subnet mask
• Default gateway
Ethernet default settings
The Ethernet default settings are as follows.
• IP address
192.168.100.100
• Subnet mask
255.255.255.0
• Default gateway
0.0.0.0
Reference
Pressing the TUNE button for at least 5 seconds sets the temporary IP
address setting mode.
"3-1 Using the SR-750 Series (Page 9)"
M12
Signal name
RJ45
Wire color
1
TX+
1
White/Orange
2
TX-
2
Orange
3
RX+
3
White/Green
4
RX-
6
Green
5
V-
7
White/Brown
6
V-
8
Brown
7
V+
5
White/Blue
8
V+
4
Blue
4
5
1
8
7
3
6
2
Pin number
Not PoE
PoE-TypeA
PoE-TypeB
1
TX+
TX+/ V+
TX+
2
TX-
TX-/ V+
TX-
3
RX+
RX+/ V-
RX+
4
RX-
RX-/ V-
RX-
5
―
―
V-
6
―
―
V-
7
―
―
V+
8
―
―
V+
Signal name
TX+/ TX-
Sent signal
RX+/ RX-
Receive signal
V+/ V-
PoE power source
Communication Function
Function Outline
Ethernet communication of the SR-750 Series is available with the following
functions:
Socket communication function
Sends read data of the SR-750 Series via socket communication.
Control the behavior of the SR-750 or change the settings via Ethernet by sending
operation and configuration commands to the command send/receive port.
Communication protocol: TCP
PLC link function (only for MELSEC and KV Series)
The PLC link is created via Ethernet.
Compatible PLCs are MELSEC Series and KV Series.
85)"
Communication protocol: UDP
PROFINET
The SR-750 Series can make PROFINET communication.
For details, refer to
Communication protocol: PROFINET
EtherNet/IP function
The SR-750 Series can be connected as an EtherNet/IP adaptor.
For details, refer to
Communication protocol: EtherNet/IP
FTP function
The SR-750 Series operates as an FTP server or an FTP client and can transfer
scanned image data or the setting file.
Communication protocol: FTP
Communication protocols for other functions
• Communication with Multimonitor: UDP
• Communication with FileView: FTP
• Master/Slave function: UDP
Port Numbers
This section describes the port numbers available on the SR-750 Series.
*1 9013, 9014, 9015, 5920, and 44818 cannot be set as they are reserved for the
reader system.
*2 When 9004 (initial value) is set, the command transmission/reception and the
data output occur at the same port. If you want to assign different ports to the
command transmission/reception and the data output, change the port number.
*3 Data port 2 performs client operations only.
Port Name
Communication
Method
Listen port/
Remote Port
Communication
Protocol
SR-750 Series
Port Number
Command port
Socket
communication
Listen port
TCP
9004 *1 *2
Data port 1
Socket
communication
Listen port
TCP
9004 *1 *2
Remote port
TCP
1024 to 65535
Data port 2 *3
Socket
communication
Remote port
TCP
1024 to 65535
PLC link
communication
Remote port
UDP
1024 to 65535
FTP communication
port
FTP
communication
―
FTP
20: FTP data port
(ACTIVE mode)
21: FTP service port