E SR-750 UM

Operation status on the multiple LED indicator

„

Run mode

In Run mode, the multiple LED displays a number, letter, or other symbol.

„

Quick setup code reading mode

In Quick setup code reading mode, the multiple LED displays a number, alphabet,
etc.

„

Test Mode

In Test mode, the multiple LED displays measurement results.

Multiple LED

indicator

Display
content

Operation

Meaning

0 to 10

When reading
successful

The parameter bank number is displayed
(1 to 10).
When the parameter bank is 10, the first
digit value and "1" are displayed alternately.

"3-3 Alternate Function (Page 11)"

P

Preset

Preset successful

"3-5 Preset/Verification Function

(Page 14)"

2 points

light up

Laser pointer
emission

The laser pointer is turned on when the

button is pressed quickly.

2 points
flashing

Set the
communication
parameters of the
RS-232C to the
default state.

Press and hold the

button for at least

6 seconds. The LED flashes and the RS-
232C communication condition returns to
the factory default state.

2 points
flashing

Temporary IP
address setting
mode

Press the TUNE button for at least 5
seconds. The LED flashes in the
temporary IP address setting mode.

L

TUNE button lock

The

button is locked according to the

settings. The laser pointer cannot be turned
on and quick calibration cannot be performed.

NG

Saving the read
error image

The LED lights up while the read error
image is being written into the ROM.

"3-7 Image Saving Function (Page 16)"

E

←→

Error code

Error occurred.

This shows that an error, such as buffer
over or IP address duplication has
occurred.
E and error code (number) lights up
alternately.

All LEDs

light up

At power-on

All LEDs light up for 500 ms when the
power is turned on.

Multiple LED

indicator

Display
content

Meaning

C

←→

C: Starts reading the quick setup code.
Numeric value: The number "C" of quick setup codes being
read and the numeric value are displayed alternately.

d

Reading successful or program successful

F

Reading failed or program failed

Multiple LED

status

Reading rate

measurement

(%)

Processing time

(ms)

Position

OK/NG/ERR

LED

5 bars lit

90 to 100

Up to 99

LEVEL 5

Green

4 bars lit

70 to 80

100 to 199

LEVEL 4

Green

3 bars lit

50 to 60

200 to 299

LEVEL 3

Green

2 bars lit

30 to 40

300 to 399

LEVEL 2

Green

1 bar lit

10 to 20

400 or more

LEVEL 1

Green

0 bars lit

Reading error

Red

Numeric

value

„

Other operations

In the quick calibration operation, the multiple LED displays bars, a number, or a
letter.

Error indications on the multiple LED indicator

1-3

System Configuration and
Setup Flow

System configuration

The SR-750 Series has the following configuration.

Action

Multiple LED

indicator

Display content

Meaning

Quick
calibration

Bar LEDs light up

in series.

This shows the progress of the quick
calibration.

Bar LEDs and

upper 2 points

light up.

The quick calibration is complete and the
test mode is running. Changing the
position of the code fluctuates the bar
LEDs.

F

Quick calibration failed
(Data for successful quick calibration was
not provided.)

H

Quick calibration failed
(Data for successful quick calibration was
provided.)

d

Saving complete

Display
content

Description

E0, E1

Main unit system error
* Abnormal operation of the main unit. Contact your nearest KEYENCE office.

E2

Configuration file reading error, image save error
* If the operation is not restored even after the main unit is initialized, there may

be problems with the main unit . Contact your nearest KEYENCE office.

E3

PROFINET error

E4

Transmission buffer overflow

E5

IP address duplication error

E6

Main unit system firmware update error

E7

PLC link error

E8

Script error

SR-750 Series

Setup PC

Ethernet

AutoID Network
Navigator

Host

PC

PLC

Ethernet

EtherNet/IP

RS-232C

I/O terminal

PROFINET